Thank You For Purchasing Dustbane's EnviroFlex!
Please use this equipment carefully and observe all warnings and cautions.
The package should contain:
• Proportioner unit
• Discharge tubes
• Instruction sheet
• Wall chart
• Product labels

Important Safety Instructions:

WEAR
working in the vicinity of all chemicals, filling or emptying equipment, or changing metering tips.
ALWAYS
ALWAYS
ALWAYS
Exercise CAUTION when maintaining your equipment.
ALWAYS
are firmly screwed or latched into position.
ATTACH
KEEP
NOTE
be mounted so that the bottom of the cabinet is above the overflow rim of the sink.

Installation and Maintenance:

1.
Find a suitable place close to water source for the unit. Mounting bracket should be installed approximately 5' from
the floor. Level bracket and mark holes. Drill 5/16" holes and install mounting anchors and screws in the bracket.
2.
Remove dispenser cover by first pulling to remove the knob from the EnviroFlex valve, then depressing tabs on side
of the dispenser and pull the cover forward and off.
3.
Hang cabinet on bracket. Mark hole for lower cabinet screw. Remove cabinet and drill 9/32" hole. Install anchor
and screw in lower cabinet hole. When mounting the unit, do not mount more than 5 feet from the floor. Also, never
mount your concentrate container higher than the unit. Keyhole slots are also provided in the back of the cabinet
if the mounting bracket are not used.
4.
NOTE: IT IS REQUIRED THAT A SAFETY SCREW BE INSTALLED.
of the dispenser. Remove the dispenser from the mounting rail by rotating locking tabs toward the outside
of the dispenser then lifting the dispenser off of the mounting rail. Drill 9/32" hole and install anchor. Reattach the
dispenser to the mounting rail (see #4). Install security screw through the back of the dispenser into anchor in the wall.
5.
Select metering tips (up to 4) for the EnviroFlex valve (see next two sections). Push each tip firmly into a separate hose
barb extending from the selector valve. A tip with no hole (clear plastic) can be used to block any valve port being used
(this may be used for dispensing water only).
6.
Install four (4) 5.5" precut lengths of tubing onto the four hose barb ports of the EnviroFlex valve. Insert four in-line check
valves, with arrows pointing toward the EnviroFlex valve, into the open ends of the pre-cut lengths of tubing.
7.
Cut supply tubing provided into separate supply tubes for each product to be dispensed. Supply tubes should reach
from in-line check valve barb to bottom of concentrate container. Push one end of supply tube over the hose barb
of the in-line check valve. Slide weight over end of each tube, then install foot strainers on ends of supply tubes before
placing into concentrate containers.
IF NECESSARY
8.
Connect water supply hose of at least 3/8"ID to water inlet swivel. (Minimum 25 PSI pressure, with water running,
is required for proper operation.) Connect opposite end of hose to water supply. Turn water supply on. Replace
dispenser cover. Hook two bottom latches, and swing up to snap over button on the top of dispenser. Reinstall knob
for EnviroFlex by pushing knob firmly onto stem.
9.
A short discharge tube is used with the 1 GPM eductor; minimum tube length is 8 inches (20 cm) for proper operation.
Longer tubes (6 feet) are used with a 3.5 GPM eductor. Do not remove the flooding rings from inside the tubes. Slide end
of tube with flooding ring over eductor discharge outlet. (Repeat for all discharge outlets.) Hooks may be installed
on longer tubes to allow discharge tube to conveniently hang from dispenser when not in use.
• Install kit including:
protective clothing and eyewear when dispensing chemicals or other materials or when
observe safety and handling instructions of the chemical manufacturer.
direct discharge away from you or other persons or into approved containers.
dispense cleaners and chemicals in accordance with manufacturer's instructions.
reassemble equipment according to instruction procedures. Be sure all components
only to tap water outlets (85 PSI maximum)
equipment clean to maintain proper operation.
if the unit is used to fill a sink or discharge hose can be placed into a sink, the unit must
REMEMBER TO CHECK FOOT STRAINERS PERIODICALLY FOR CLOGGING: CLEAN
(3) Screws, (3) Anchors, (4) In-line check valves,
(2) Metering tips kit, (4) Weights,
(21') Supply tubing, (4) Foot strainers,
(1) Select lever, (1) Hose hook
Mark the wall using one of the lower holes in the back