Electrodes - Deflector Setting; Pump Pressure Adjustment - deville D10 N - PR Mode D'emploi

Bruleurs fioul domestique
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

After having installed the nozzle, check the correct position of the electrodes and de ector according to the
following levels. It is adviseable to check levels after every intervention on head.
The pump pressure is pre-set during production at 12 bar.
For controlling pressure use an oil bathed manometer.
The pressure can be adjusted from 7 to 14 bar.
S
U
N
To allow the DANFOSS BFP 21 pump to t a one-
pipe system, proceed as follows:
- Loosen the screw A.
- Remove the screw B from its seat.
- Tighten the screw A.
- Insert the supplied plug in the hole C.
To allow the SUNTEC AS pump, remove the screw by-pass accessible from the hole of the return. Close the hole
return with the stopper.

ELECTRODES - DEFLECTOR SETTING

2÷3
2÷3

PUMP PRESSURE ADJUSTMENT

T
E
C
TRANSFORMATION IN ONE-PIPE PUMP
D
A
N
F
O
S
S
17
3
6÷6,5
INDEX
1
Intake
2
Return
3
Nozzle
4
Pressure Adjustment
7

Publicité

Table des Matières
loading