6.0 Certification/approvals

lECEx units

Gas (G) certified units

Certified to IEC60079-0, IEC60079-1 and IEC60079-7
Ex d IIC unit (IEC certification No. lECEx BAS 13.0112X)
Ex db IIC T
(T
.) Gb
G
amb
Ex de IIC unit (IEC certification No. IECEx BAS 13.0114X)
Ex db eb IIC T
(T
) Gb
G
amb.
See special conditions for safe use for ambient temperature
ranges and T-ratings.
The IECEx certificate and product label carry the IECEx
equipment protection level marking:
Gb
Where Gb signifies suitability for use in a Zone 1 surface
industries area in the presence of gas.
Gas & Dust (GD) certified units
Certified to IEC60079-0, IEC60079-1, IEC60079-7 and
IEC60079-31
Ex d IIIC unit (IEC certification No. IECEx BAS 13.0113X)
Ex db IIC T
(T
) Gb
G
amb.
Ex tb IIIC T
(T
) Db IP6X
D
amb.
Ex de IIIC unit (IEC certification No. IECEx BAS 13.0115X
Ex db eb IIC T
(T
) Gb
G
amb.
Ex tb IIIC T
(T
) Db IP65/66*
D
amb.
*depending on outer flare type (Short flare – IP65, Long
flare – IP66)
See special conditions for safe use for ambient tempera-
ture ranges and T-ratings.
The IECEx certificate and product label carry the IECEx
equipment protection level markings:
Gb and Db
Where Gb signifies suitability for use in a Zone 1 surface
industries area in the presence of gas.
Db signifies suitability for use in a Zone 21 surface
industries area in the presence of dust.

ATEX units

Gas (G) certified units
Certified to EN60079-0, EN60079-1 and EN60079-7
Ex d IIC unit (ATEX certification No. Baseefa
13ATEX0229X)
Ex db IIC T
(T
) Gb
G
amb.
Ex de IIC unit (ATEX certification No. Baseefa 13ATEX0232X)
Ex db eb IIC T
(T
) Gb
G
amb.
See special conditions for safe use for ambient temperature
ranges and T-ratings.
The ATEX certificate and product label carry the ATEX group
and category marking:
II 2 G
Where:
Signifies compliance with ATEX
II
Signifies suitability for use in surface industries
2
Signifies suitability for use in a zone 1 area
G
Signifies suitability for use in the presence of gases
Gas & dust (GD) certified units
Certified to EN60079-0, EN60079-1, EN60079-7 and
EN60079-31
Ex d IIIC unit (ATEX certification No. Baseefa13ATEX0231X)
Ex db IIC T
(T
) Gb
G
amb.
Ex tb IIIC T
(T
) Db IP6X
D
amb.
Ex de IIIC unit (ATEX certification No. Baseefa13ATEX0233X)
Ex db eb IIC T
(T
) Gb
G
amb.
Ex tb IIIC T
(T
) Db IP65/66*
D
amb.
*depending on outer flare type (Short flare – IP65, Long
flare – IP66).
See special conditions for safe use for ambient temperature
ranges and T-ratings.
The ATEX certificate and product label carry the ATEX
group and category marking:
II 2 GD
Where:
Signifies compliance with ATEX
II
Signifies suitability for use in surface industries
2
Signifies suitability for use in a zone 1 area
G
Signifies suitability for use in the presence of gases
D
Signifies suitability for use in the presence of dust
Sounder - dB3B
TM264 July 2020 www.eaton.com