64

2.0 SAFETY ISSUES

This furnace has been designed to deliver many years of effi cient, dependable service. With regular
maintenance, some of which requires the attention of a qualifi ed installer, service agency or gas supplier,
some of which you may do yourself, the furnace will operate satisfactorily over many heating seasons.
Please read this manual to familiarize yourself with safety procedures, operation, and routine maintenance
procedures. Figure 1 is provided to help identify the components of your furnace.
Do not use this furnace if any part has been under water. A fl ood-damaged furnace is extremely dangerous.
Attempts to use the furnace can result in fi re or explosion. A qualifi ed service agency should be contacted to
UM
inspect the furnace and to replace all gas controls, control system parts, electrical parts that have been wet or
the furnace, if deemed necessary.
FIGURE 1 - FURNACE COMPONENTS
LEGEND
1. Combustion Air Intake Fitting
2. Flame Roll-Out Switch (2)
3. Flame Sensor
4. Two Stage Gas Valve
5. Air High Temperature Limit (behind gas valve) 15. Front Manifold Cover Pressure Tap (3)
6. Vent Drain Assembly Coupling
7. Drain for Recovery Coil (3)
8. Condensate Trap
9. Two Stage Integrated Furnace Control (IFC)
10. Transformer for 24 VAC / 40VA
W415-2308 / B / 11.04.19
1
3
14
15
8
16
2
11. Burner Assembly
12. Hot Surface Igniter (HSI)
13. Two Speed Exhauster
14. Pressure Switch Assembly
16. PFC "Choke Coil" (required on ¾ and 1 Hp units)
17. Door Switch and Junction Box
18. Blower Motor
19. Circulating Air Blower
1
H25.0.1
11
12
6
5
4
13
7
18
9
10
17