Switching Fuel Sources; Stopping The Engine; Frequency Of Use; Ac Circuit Breakers - Westinghouse WGen5300DF Manuel De L'utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPERATION
Note: During Push-Button or Remote Start the engine
will automatically set the choke and begin the start
sequence. If the engine fails to start, the generator
will attempt to start the engine two more times.

SWITCHING FUEL SOURCES

Fire and explosion hazard. DO NOT add gasoline to
the fuel tank or connect the LPG/propane hose to the
generator while the generator is in operation.
The fuel source can be switched while the engine is
running if a propane tank is connected to the generator
BEFORE operation.
GASOLINE TO PROPANE
IMPORTANT: Load capacity is reduced when running
on propane. Make sure the generator can
supply enough (running) and surge (starting)
watts for the items you are powering before
switching to propane.
1. Fully open the valve on the propane tank.
2. Turn the fuel selector switch to propane operation.
3. Turn the fuel tank valve to the OFF position.
PROPANE TO GASOLINE
1. Turn the fuel tank valve to the ON position.
2. Turn the fuel selector switch to gasoline operation.
3. Turn the propane tank valve to the fully closed position.
Note: When switching to propane operation the engine
may run rough for a few seconds while it purges
gasoline in the carburetor.
If the engine stops when switching fuel sources, disconnect
all loads then restart the unit on the fuel source of choice.

STOPPING THE ENGINE

1. Turn off and unplug all connected electrical loads.
IMPORTANT: Never start or stop the generator with
electrical devices connected.
2. Let the generator run with no load for several minutes to
stabilize internal temperatures of the engine.
3. Push and hold the START/STOP button for one second
or push STOP on the remote start key fob for one
second.
Note: Alternately, if the generator is used infrequently, turn
the fuel tank valve to the OFF position to limit the
residual fuel remaining in the carburetor float bowl.
16 | Westinghouse Outdoor Power Equipment, LLC
DANGER
The engine will stop when fuel in the carburetor and
fuel line is exhausted.
4. Push the battery switch to the OFF position.
5. If operating on LPG, turn the propane tank valve to the
fully closed position.

FREQUENCY OF USE

If the generator will be used on an infrequent or intermittent
basis (more than one month before next use), refer to
the Battery Maintenance and Storage sections of this
manual for information regarding battery charging and fuel
deterioration.

AC CIRCUIT BREAKERS

The circuit breakers will automatically switch OFF if there
is a short circuit or a significant overload of the generator
at each receptacle.
If an AC circuit breaker switches OFF automatically,
check that the appliance is working correctly and it does
not exceed the rated load capacity of the circuit before
resetting the AC circuit breaker ON.
Circuit Breakers
ON
OFF
Push to Reset

Publicité

Table des Matières
loading

Table des Matières