Installation - Other Fixtures (continued)
5
Replacing Sockets
□ Remove current sockets.
□ Insert non-shunted sockets
(C) into the fixture brackets
(B) to replace the previous
sockets.
NOTE: These LED tubes (A) only work with non-
shunted sockets (C).
7
Replacing the Ballast Cover
□ Replace the ballast cover, if necessary.
8
Installing LED Tubes
□ Install LED tubes (A) with the end labeled "power this
end" to the wired sockets.
□ Turn the tube a quarter turn to lock it in place.
□ Affix the UL Safety Sticker (CC) in a visible location.
C
C
A
AA
6
Wiring the Sockets
□ Push the solid copper jumper wires (AA) into the holes on the
non-shunted sockets (C).
□ Wire each socket as noted below in the wiring diagram.
C
AA
9
Attaching the fixture lens
□ Reattach the lens to the fixture.
□ Make sure the lens is secure.
10
Restoring Power
□ Restore power at the electrical panel.
□ Turn on the light switch to activate the fixture.