1. Use of the Connection Terminals

When using the connection terminals, use a suitable, pointed object (e.g. ball point pen
tip) and only use slight pressure (max. 1 kg). The supply cable must only have a cross-sec-
tion of 0.2-0.75 mm
, the supplied cable is 0.5 mm
2
Do not tin coat the ends of the supply cables and do not apply ferrules.

2. Dip Switches

DIP
OFF
1
Full volume
Green light of the LEDs flashing in normal oper-
2
ating mode
No alarm: 0 V
Output
Alarm for propane/butane/narcotic gas: 30 s
3
SIR+
12/24 V
Alarm for CO: 2x10 s 12/24 V
Output
4
If dip 4 is off, then see function of dip switch
SIR+
Warning of propane/butane and KO gases with
low concentrations (standard)
5
Not used
6
Not used
7
Not used
8
. The ends should be stripped 7-9 mm.
2
ON
Reduced volume
Green light of the LEDs constant, but dimmed, in
normal operating mode
No alarm: 0 V
Alarm: 12/24 V during the entire duration of the
alarm (function intended for vibration mat, flash
or fan)
No alarm: 12/24 V
Alarm: 0 V during the entire duration of the alarm
(intended for valve control)
Warning of propane/butane and KO gases as per
the following standards, DIN EN 50194-1, DIN
EN 50194-2