HOSE KIT - Item. 35241
Purge the hose. To do this, close the gas cylinder valve and burn off the gas that is still in the
circuit by pressing the trigger.
When there is no more gas in the hose, disconnect the regulator from the cylinder.
Disconnect the quick connector from the heat-shrink gun.
Unscrew the nut that is in contact with the regulator using two open ended spanners
Replace the hose. (item. 35241)
Re-tighten the nut on the regulator using two open ended spanners; tighten firmly (to a torque of
16 N.m). Do not just hand-tighten only.
Re-connect the quick connector to the equipment. Carry out the start-up checks.
Remark: for an explanation of the hose manufacture date and for further details please refer to the
EXPRESS ISO 3821 Hose technical data sheet.
DEFLECTOR - Item. 35088
AIR CLIP - Ref. 35198
35280 g – GB-FR-NL-ES-PT-PL-Z0
35241
911
963/10
To prevent too much heat being transferred towards
the operator's hand.
Using the hex spanner supplied with the equipment fit
the deflector as indicated above.
Firmly tighten (16 N.m)