Overall Dimensions; Power Supply; Junction Box Location - Thermador CEF Série Instructions D'installation

Masquer les pouces Voir aussi pour CEF Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation Instructions
Models CEF304, CET304, CEP304: Width 31"
Models CEF365, CET365, CEP365: Width 37"
Models CEP456: Width 46"
All Models:
Depth 21-5/8"
Height above countertop: 1/4"
A

Overall Dimensions

Cabinet
Bottom
(unprotected)
Building
Back
Wall
C
Minimum Cabinet Clearances
E
MODEL NOs.
CEF304,CEP304,
CET304
CEF365,CEP365,
CET365
CEP465
*(For solid surface countertop installations, use maximum cutout dimensions and consult solid surface manufacturer for specific directions.)
Building
Side Wall
30" Min.
(762mm)
Cooking
Surface
DIM
Minimum in./(mm)
B
19 7/8 / (505)
C
28 3/4 / (731)
B
19 7/8 / (505)
C
34 3/4 / (883)
B
19 7/8 / (505)
C
43 3/4 / (1111)
Models: CEF304, CEF365, CET304, CET365, CEP304, CEP365, CEP456
Models CEF304, CET304, CEP304: 30 Amp circuit
breaker
Models CEF365, CET365, CEP365: 40 Amp circuit
breaker
Models CEP456: 50 Amp circuit breaker
CEF, CET and CEP
Models:
B

Power Supply

12" Approximate
D

Junction Box Location

COUNTER CUTOUT DIMENSIONS
Maximum* in./(mm)
PAGE 2
240 Volt, 4 Wire, 60 Hz
208 Volt, 4 Wire, 60 Hz
Conduit
(Approx. 3 Ft)
J Box
20 / (508)
20 7/8 (530)
20/ (508)
35 / (891)
20 / (508)
43 7/8/ (1114)

Publicité

Table des Matières
loading

Table des Matières