Unit Shuts Down in 15‐20 
minutes with an "E‐2" code 
on control board. 
  
  
"E‐3" Code on Control Board 
(Overfire) 
  
  
"E‐4" Code on Control Board 
(Proof of flame lost) 
  
  
  
Notes: 
  
1. Whenever instructed to check/replace the vacuum sensor, also check for loose or cracked vacuum hose.  Also, 
be certain the vacuum measurement port in the firebox is kept clean (clean with a pipe cleaner or brush, do not 
use a vacuum to clean). 
  
2. To restart and clear an error code displayed on the control board, push the "ON" button and the unit should 
reset the error and restart. 
  
3. If you are uncertain about the meaning of an error code or have any questions at all, PLEASE contact 
Technical Support at (800)245‐6489. 
 
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
1. Loose thermal sensor. 
2. Control board settings. 
3. Failure to light pellets. 
1. Convection (Room Air) blower failure.  1. Check convection blower for 
2. Partially blocked flue. 
3. Using fuel other than premium wood 
pellets. 
1. The hopper is empty. 
2. The hopper lid was left open too long 
during refueling. 
3. Component failure. 
4. Blower speed is set too high, cooling 
firebox too rapidly. 
  
 
 
 
33
QUESTIONS.
1. Check both sides of thermal 
sensor connection (exhaust blower 
and control board). 
2. Start stove on minimum Heat 
Range 5 to ensure a good fire is 
started. 
3. Check igniter for buildup or 
failure. 
proper function, replace if 
necessary. 
2. Check flue for obstructions. 
3. Use ONLY premium wood pellets 
in this stove. 
1. Refill the hopper with pellets and 
restart the stove. 
2. Keep the hopper lid open for the 
shortest interval possible when 
refueling.  The safety switch stops 
the auger when the hopper lid is 
open. 
3. An auger motor failure or 
combustion motor failure can 
sometimes result in an "E‐4" code. 
4. Operate the stove with the 
blower speed and heat range at the 
same value. 
  
  
  
  