To adjust flame low setting
Identify which burner is exhibiting too high or too low of simmer rate via manifold
panel graphics.
Simmer Set
Screw
Small
Screwdriver
Valve Stem
Install_NX58M9960PS_DG68-01009A-01_EN+MES+CFR.indb 27
1.
Rotate a knob to LO position and
remove the knob from the valve stem
while the flame is lit.
2.
Carefully push the screw driver into
the C channel of the valve, until it hits
the simmer set screw. Make sure the
screwdriver flathead is seated into the
set screw groove.
3.
Rotate valve set screw clockwise to
decrease LO setting flame output, or
rotate set screw counter clockwise to
increase LO setting flame output.