Rotational speed and standstill monitoring with suitable encoder, automatic mode; for manual start: ON/OFF pushbutton to T4/ST; for automatic start:
jumper to T4/ST; suited up to SIL3, Performance Level e, Cat. 4 (Requirement for Cat. 4 is, that during longer periods of standstill a forced dynamisa-
tion (t < 24 h) has to be carried out).
L
On
A1+
A1
T4
T4
ST
ST
MAG
MAG
EO
UH5947
RJ45
A2
T3
RF1
RF2
N
Two-channel rotational speed and standstill monitoring by means of two NPN or PNP proximity sensors; automatic mode; safety gate monitoring active;
for manual start: ON/OFF pushbutton to T4/ST; for automatic start: jumper to T4/ST; suited up to SIL3, Performance Level e Cat. 4 (Requirement for