Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

SK100
INSTALLATION
The installation must be done fixing SK100 card in the burglar alarm control unit of the
PROTEC series which has proper connections on the bottom. If Sk100card is installed on Tm
series control units is necessary to use the plastic support in equipment.

CENTRAL UNIT

+
+
Alarm
-
Sir
S.A.
NA
C
NC
(*) This connection is optional; if a false electric key is inserted in the connector, the 24h anti-
sabotage protection will be active.
PROGRAMING OF THE OPERATION
SK100 works according to two kind of operation::
MONOSTABLE
The insertion of the electric key in the connector causes the excitation of relay "output", that
will discharge itself after some instants. In this way you have a pip working that is preferable to
control automation systems for gates.It is thus obtained a pulse operation which lends
itself to installation on the central PROTEC6GSM, TM600GSM and TM600P. Also
needed for installation on a central automation for gates.
BISTABLE
The insertion of the electric key in the connector causes the excitation (or discharge)of the
relay output, just changing the state it was before inserting the key. In this way, we have the
step-by-step operation, that is better to control burglar alarm control units.
6
-
-
+
+
V
12Vcc int12V Chiave
led key
Remove
the bridge
A
B
C
D
SKI/NL
(in dotation)
JMP1 = Off
JMP1 = On
SK100
R
Com
zone
24H Z1
Z2
Z3 Z4 Z5 Z6 Z7 Z8
In series
to 24h (*)
4S
security
In other 3
key reader max (optionals)