7.. OPEN BEAM FUNCTION

With this function, combined or not with the battery kit, the following beam behaviour patterns are possible:
w
ithout bAttery kit
Dip-switch 4=OFF: If there is a mains power cut, the beam stays stopped in the position it is in. When mains power
returns, after 2 seconds the control unit automatically commands the beam to close, preparing itself for normal
operation.
Dip-switch 4=ON: If there is a mains power cut, the beam stays stopped in the position it is in. When mains power
returns, a pulse must be sent to ensure that the control unit resumes normal operation.
w
ith bAttery kit
Dip-switch 4=OFF: If there is a mains power cut, the beam continues operating normally. At every opening, the
flashing light flashes twice consecutively, at intervals of 3 seconds between the flashes, for a maximum time of
30 seconds, signalling that the beam is battery powered. When mains power is resumed, the automated system
resumes normal operation.
The number of cycles possible with the automated system battery powered, depends on the battery
charge level, on the time elapsing since mains power was stopped, and on the conditions of the
automated system, external temperature etc...
Dip-switch 4=ON: In the event of a mains power cut, the automated system automatically opens the beam,
stopping it in vertical position and disabling all the commands. When mains power returns, if automatic logic
was selected, the automated system automatically performs a closing movement preparing itself for normal
operation. Vice-versa, if manual logic was selected, the automated system waits for a pulse to resume normal
operation.
The control board has an integrated 2-channel decoding system (DS, SLH, LC/RC) named OMNIDEC. This system
makes it possible to memory-store both OPEN command and the OPEN/CLOSE command of the automated system
- this is made possible by an additional receiver module and radio controls on the same frequency.
• The 3 types of radio codes (DS, LSH, LC/RC) cannot coexist. Only one radio code can be used at a time. To
change over from one code to another, you must delete the existing one (see paragraph 8.3), and repeat
the memory-storage procedure.
• Fitting and, if necessary, removing the receiver module must be done only after cutting power to the board.
• The receiver module can only be inserted in one position. Orient the module correctly without forcing.

8.. Memory storage of DS radio controls

A maximum of two codes can be stored. One on the OPEN channel and one on the OPEN/CLOSE channel.
1.
On the DS radio control, select the required ON-OFF combination for the 12 dip-switches.
2.
On the control unit, press the push-button of the channel you wish to memory store, P2 for the OPEN channel or
P3 for the OPEN/CLOSE channel.
3.
The relevant LED on the control unit begins to flash - release the push-button.
4.
On the radio control, press the push-button with which you wish to associate the selected channel.
5.
The LED on the control unit lights up on steady beam for about one second, signalling that the radio control was
stored in the memory, then it resumes flashing.
6.
To add other radio controls or memory store the second channel, repeat the operations from point 1

8.2. Memory storage of SLH radio controls

You can memory store up to a maximum of 250 codes, subdivided between the two channels, OPEN and
OPEN/CLOSE.
1.
On the radio control, simultaneously press and hold down push-buttons P1 and P2 (see radio control instructions).
2.
After about one second, the LED of the radio control begins to flash.
3.
Release both push-buttons.
4.
Press and hold down push-button P2 or P3 on the board to respectfully memory store the OPEN or OPEN/CLOSE
channel. The relevant LED begins to flash.
5.
Simultaneously press the push-button of the radio control with which you wish to associate the selected
command.
6.
Check if the LED relating to the command being memory stored (DL6 for the OPEN channel or DL7 for the OPEN/
CLOSE channel) lights up on steady beam for about two seconds to confirm correct memory storage.
7.
To finish programming, press twice in close succession, the push-button of the memory stored radio control.
The automated system will perform an opening manoeuvre - make sure that there are no obstacles inside the
operating range.
8.
To memory store the other channel, repeat all the procedure from point 1.
To add other radio controls, transfer the code of the memory-stored push-button of the radio control to the relevant
push-button of the radio controls to be added, repeating the memory storage procedure or observing the following
procedure:
On the memory stored radio control, simultaneously press and hold down push-buttons P1 and P2 (see radio
control instructions).
The radio control LED begins to flash.
Release both push-buttons.

8. MEMORY STORING THE RADIO CODE