BTL7-A/C/E/G_ _ _-M_ _ _ _-A/B/Y/Z(8)-S32/S115/S135/KA_ _
Micropulse Transducer - Rod Style
3

Construction and function

Output signal with rising
characteristic:
BTL7...KA_ _
BTL7...S115
Calibration device
Version
D1
...-A/B/Y/Z-...
10.2 mm
...-A/B/Y/Z8-...
Fig. 3-1: BTL7...A/B/Y/Z(8)... transducer, construction and function
3.1
Construction
Electrical connection: The electrical connection is made
via a cable or a connector (see Ordering code on page 25).
BTL housing: Aluminum housing containing the
processing electronics.
Mounting thread: The transducers with Ø 10.2 mm have
an additional thread at the end of the rod to support larger
nominal lengths. We recommend assembling this
transducer on the mounting thread:
BTL7-...-A/B: M18×1.5
BTL7-...-Y/Z: 3/4"-16UNF
Magnet: Defines the position to be measured on the
waveguide. Magnets are available in various models and
must be ordered separately (see accessories on page 23).
6
english
Error signal
100 %
0 %
Mounting surface
BTL7...S32/S135
G
Thread
M4x4/6 deep
8 mm
No thread
Null point
End point
B: 30-1 mm
Z: 2"-0.04"
Nominal length =
Measuring range
1)
2)
Magnet
Thread size:
B: M18x1.5
Z: 3/4"-16UNF
Mounting surface
A: 30-1 mm
Y: 2"-0.04"
1)
Nominal length: Defines the available measuring range.
Rods with various nominal lengths from 25 mm to
7600 mm are available depending on the version:
Ø 10.2 mm: Nominal length from 25 mm to 7600 mm
Ø 8 mm: Nominal length from 25 mm to 1016 mm
Damping zone: Area at the end of the rod that cannot be
used for measurements, but which may be passed over.
Calibration device: Additional device for calibrating the
transducer.
Damping zone 1)
Unusable area
2)
1)
Not included in scope
2)
of delivery
Thread size:
A: M18x1.5
Y: 3/4"-16UNF