Construction And Function; Construction - Balluff BTL6-P510-M Série Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

BTL6-P510-M _ _ _ _ -E2/E28-KA _ _ /LA _ _
Magnetostrictive Linear Position Sensor – Rod Style
3

Construction and function

BTL6-...-KA
Mounting
surface
25.2
30-1
1)
21
17
Ø24
25
45°
4
O-ring
7.5
Support ring
Version
D1
...-E2-...
10.2 mm
...-E28-...
8 mm
1) Unusable area
2) Not included in scope of delivery
Fig. 3-1:
BTL6-P510-...-E2/E28-..., construction and function
3.1

Construction

Electrical connection: The electrical connection is made
via a cable or strands and is permanent (see Type code on
page 13).
Housing: Housing containing the processing electronics.
Fastening: The BTL can be fastened in a fitting bore
(Ø 48 H8), but must be sealed with the provided O-ring
and support ring. The body of the BTL is fastened using
3 M5 threaded pins at a 120° angle. The BTL with
Ø 10.2 mm has an additional thread at the end of the rod
to support larger nominal lengths.
Magnet: Defines the position to be measured on the
waveguide. Magnets are available in various models and
must be ordered separately (see Accessories on page 12).
6
english
Nominal length =
Measuring range
2)
Magnet
G
Thread
M4x4/6 deep
No thread
1)
Damping zone
63.5
G
BTL6-...-LA
25.7
21
3
25
4
7.5
Nominal length: Defines the available measuring range.
Rods with various nominal lengths from 50 mm to
2000 mm are available depending on the version:
Ø 10.2 mm: Nominal length from 50 mm to 2000 mm
Ø 8 mm: Nominal length from 50 mm to 1016 mm
Damping zone: Area at the end of the rod that cannot be
used for measurements, but which may be passed over.
Ø 48 f7
Ø 38.9
Ø 48 f7
Ø 38.9

Publicité

Table des Matières
loading

Table des Matières