Electrical connections
Be sure your appliance is properly
installed and grounded by a qualified
technician.
Ask
recommend a qualified technician or
an authorized repair service.
This appliance is manufactured is with
a green GROUND wire connected to
the oven body. After making sure that
the power has been turned off, connect
the flexible conduit from the oven to the
junction box using a U.L. listed conduit
connector. Figures A and B and the
instructions provided below present
the most common way of connecting
the ovens.
Your local codes and ordinance, of
course, take precedence over these
instructions.
Complete
connections according to local codes
and ordinance.
"WARNING" Risk of Electric Shock,
frame
grounded
appliance through a connection.
Ground through the neutral conductor
is prohibited for new branch-circuit
installation (1996 NEC); mobile homes;
and recreation vehicles, or in an area
where local codes prohibit grounding
through the neutral conductor. For
installations where grounding through
the neutral conductor. For installations
where grounding through the neutral
conductor is prohibited:
Disconnect the ground from the
neutral at free end of conduit;
Use grounding terminal or lead to
ground unit; and usual procedure.
your
dealer
to
electrical
to
neutral
of
17
3-Wire branch circuit (for US only)
Refer to Figure A, where local codes allow
the connection of GROUND wire from the
oven to the branch circuit NEUTRAL wire
(gray or white colored wire):
- If local codes permit, connect the green
GROUND wire from the oven and the white
wire from the oven to the branch circuit
NEUTRAL wire (gray or white colored wire).
- Connect the red and black leads from the
oven to the corresponding leads in the
junction box.
A
4-Wire branch circuit (for US and
CANADA)
Refer to Figure B:
- Connect the green GROUND wire from the
oven to the GROUND wire in the junction
box (bare or green colored wire).
- Connect the red and black leads from the
oven to the corresponding leads in the
junction box.
- Connect the white wire from the oven to the
NEUTRAL (gray or white) wire in the junction
box.
B