Dew point mode/condensation moisture indicator
The dew point temperature is the point the temperature must drop below for the air to
precipitate its water vapour in the form of droplets, mist or dew. Condensation water
therefore occurs for example when the temperature of an inside wall or window reveal
is lower than the dew point temperature of the room. These areas are then damp and
are a breeding ground for mildew/mould with possible material damage.
The CondenseSpot Plus calculates the dew point with the integrated sensors for ambient temperature
and relative humidity. At the same time, the surface temperature of objects is determined with the aid of
infrared temperature measurement. By comparing these temperature it is possible to identify areas that
are exposed to the risk of condensation moisture. The condensation moisture indicator (b) displays the
result in the form of a bar graph, supported by visual and acoustic signals indicating the high probability
of condensation moisture occurring.
No risk of condensation
oisture
The condensation moisture indicator (b) is shown in all modes.
The device therefore constantly shows the risk level of condensation moisture.
The measured values for relative humidity and ambient temperature can be called up:
14
EN
Slight risk of condensation
moisture
„dP" symbol flashing
SET
Risk of condensation moisture
„dP" symbol flashing with
acoustic signal
SET