Digital Multimeter
Instruction Manual
RS232
HFR
ACDC LV
AutoPeak HOLD
STORE
RECALL
MAX
MIN
AVG SETUP
RANGE
HFR
DIGIT
mV
V
OFF
A
mA COM V
MAX
MAX
FUSED
10A
FUSED
#61-497
#61-498
MAX-MIN
FH AVG
AC+DC
µmVAF
G'F'C%
kM Hz
dB
LOG RATE
dBm
DATA LOG
ENTER A-HOLD
CANCEL P-HOLD
A
Hz%
°C°F
Hz °C
600V
CAT IV
1000V
CAT III
mA
Register your product and access more information at
www.idealindustries.com
Read First: Safety Information
Understand and follow operating instructions carefully. Use the meter,
test leads and all accessories only as specified in this manual; otherwise,
the protection provided by the meter can be impaired.
WARNING
To avoid possible electric shock, personal injury or death, follow
these guidelines:
• Do not use if meter appears damaged. Visually inspect the meter to
ensure case and jaws are not cracked.
• Inspect and replace test leads if insulation is damaged, metal is
exposed, or probes are cracked. Pay particular attention to the
insulation surrounding the connectors.
• Always ensure the meter, test leads and all accessories meet or exceed
the measurement category required in the working environment. (i.e.
CAT rating)
• Note that the measurement category and voltage rating of combinations
of the meter, the test leads, and the accessories is the lowest of the
individual components.
• Do not use meter if it operates abnormally as protection maybe
impaired.
• Do not use during electrical storms or in wet weather.
• Do not use around explosive gas, dust, vapor, amperage or in damp or
wet environments.
• Do not apply more than the rated voltage to the meter.
• Remove the test leads from the input jacks before measuring current.
• Replace battery as soon as battery indicator
readings.
• Remove the test leads from the meter prior to removing battery cover.
• Do not use without the battery and battery cover properly installed.
• Do not attempt to repair this unit as it has no user-serviceable parts.
• Use the proper terminals, functions and range for your measurements.
• Never ground yourself when taking electrical measurements.
• Connect the black common lead to ground or neutral before applying
the red test lead to potential voltage. Disconnect the red test lead from
the voltage first.
• Keep fingers behind the guard rings of the probe tips.
• Voltages exceeding 30VAC or 60VDC pose a shock hazard so use
caution.
appears to avoid false
2
Table des Matières
loading

Sommaire des Matières pour IDEAL 61-497

  • Page 27: Multimètre Numérique

    Enregistrez votre produit et accédez à davantage d’informations sue #61-497 www.idealindustries.com #61-498 Lire en premier : Informations de sécurité Assimiler et se conformer scrupuleusement aux instructions d’utilisation. N’utiliser le multimètre que de la façon spécifiée dans le présent manuel ;...
  • Page 28: Symboles Figurant Sur L'appareil

    Illustration du panneau avant Pour vous protéger, ayez le réflexe « la sécurité d’abord ». 1. Affichage LCD: 4000/40000 unités pour le 61-497. • Observez les codes de sécurité locaux et nationaux. 10000/100000 unités pour le 61-498. • Utiliser un équipement de protection individuelle approprié, comme lunettes 2.
  • Page 29: Prise De Mesures Élémentaires

    Prise de mesures élémentaires Mode de rejet de haute fréquence Le mode RHF achemine la tension à travers un filtre passe-bas pour Préparation et mise en garde avant la mesure rejeter la haute fréquence. Le point de –3dB du filtre passe-bas est : Se conformer aux règles Avertissements et Mises en garde...
  • Page 30: Test De Diode

    – + – Test de diode Mesure de la fréquence µs RS232 ACDC LV MAX-MIN AutoPeak HOLD FH AVG AC+DC µmVAF G’F’C% kM Hz PRESS STORE RECALL LOG RATE DATA LOG AVG SETUP RANGE ENTER A-HOLD – – + – DIGIT CANCEL P-HOLD °C°F...
  • Page 31 DIGIT : Maintien de crête (c.a. V / c.a. A uniquement) Appuyer Press Press AUTO AUTO AUTO AUTO AUTO Appuyer Press STORE RECALL LOG RATE STORE RECALL LOG RATE AVG SETUP DATA LOG AVG SETUP DATA LOG STORE RECALL LOG RATE STORE RECALL LOG RATE...
  • Page 32: Enregistrer Et Rappeler

    1. Enregistrer et rappeler 2. MAX / MIN / AVG ENTER Appuyer Cancel PRESS ENTER STORE STORE ENTER Appuyer PRESS Appuyer Appuyer Appuyer Appuyer PRESS PRESS PRESS PRESS Appuyer PRESS ENTER Le mode MAX/MIN/AVG enregistre les valeurs d’entrée minimale et maximale.
  • Page 33: Mode Relatif

    4. Mode relatif 5. Option de CONFIGURATION (SETUP) Appuyer sur pour changer la configuration de l’appareil. Appuyer PRESS Appuyer sur ENTER pour enregistrer la co nFiguration. AUTO ENTER Appuyer sur pour sélectionner l’article de configuration de l’appareil. Appuyer sur CANCEL pour quitter cette fonction. 5.1 Avertisseur sonore Appuyer PRESS...
  • Page 34: Fréquence De Consignation

    5.4 DANGER Le LOG RATE es la fréquence d’enregistrement du DATALOG. Quant le Appuyer PRESS curseur clignotant du menú est LOG RATE, appuyez sur le bouton Enter pour entrer sur le mode LOG RATE. Appuyez sur les boutons Haut et Bas pour sélectionner LOG RATE, puis appuyez sur le bouton Cancel pour quitter.
  • Page 35: Entretien

    En ce qui concerne les pièces de rechange ou les renseignements Bouton HFR : Affiche la version de micro logiciel concernant l’entretien, se mettre en rapport avec IDEAL INDUSTRIES, Bouton A-HOLD : Invalider AUTO BACKLIT (rétroéclairage INC. au 1-877-201-9005 ou visiter notre site web à : automatique) www.testersandmeters.com.
  • Page 36: Carractéristiques Générales

    à toute borne: Dimensions (l x L x P) 95 mm x 207 mm x 52 mm avec étui. Affichage 4000/40000 unités pour le 61-497 Accessoires : Exigences Pile (montée), conducteurs d’essai et 10000/100000 unités pour le 61-498 d’alimentation : manuel de l’utilisateur.
  • Page 37: Maintien De Crête

    CMRR > 100 dB à c.c., 50 Hz / 60 Hz (Rapport de rejet sur Résolution mini- 1 µV sur la plage 40 mV pour le 61-497, NMRR > 50 dB at c.c., 50 Hz / 60 Hz mode commun) male : 0,1 µA sur la plage de 10 mA pour le 61-498.
  • Page 38: Contrôle De Continuité

    (4) Résistance (6) Test de diode 61-497 61-497 Plage Résolution Précision Plage Résolution Précision 400,00 Ω 0,01 Ω 2,000 V 1m V ± (1,5 % + 2 d) 61-498 4,0000 KΩ 0,1 Ω ± (0,2 % + 30 d) 40,000 KΩ...
  • Page 39: Compteur De Fréquence

    (10) Température d’une utilisation abusive, de la négligence, d’un accident, d’une réparation non autorisée, d’une modification ou d’une utilisation déraisonnable de l’instrument. 61-497 / 61-498 Toutes les garanties implicites résultant de la vente d’un produit IDEAL, incluant Plage Résolution Précision sans y être limitées les garanties implicites de valeur marchande et d’adaptation...

Ce manuel est également adapté pour:

61-498

Table des Matières