Extension Cables - FLIR C336ZC1 Manuel D'utilisation

Caméra ptz 12x mpx
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4
Connecting the Camera
2. Connect the camera's power cables to a 24V AC power supply (3A or
higher).
3. Connect the camera to up to 2 alarm input devices and 1 alarm output
device.
4. Connect the camera to a self-powered microphone for listen-in audio.
5. RS-485 is for service purposes only — not required for controlling MPX
PTZ cameras.

4.1 Extension Cables

You can extend the video signal from this camera using a single extension ca-
ble between the camera and the DVR. See the table below for the maximum
cable run lengths for all supported cable types:
Specification
RG59 20AWG Conductor 95% Braid CSA/UL or C(UL) Approved
RG6 20AWG Conductor 95% Braid CSA/UL or C(UL) Approved
Analog CCTV Balun
* Long cable runs over 1000ft may be affected by electro-mechanical interfer-
ence (EMI), which can increase the amount of noise in the picture in some
installations.
#LX400046; r. 2.0/22386/22410; en-US
CAUTION
Make sure to disconnect the power adapter before installing the camera. The cam-
era will begin moving immediately when the power adapter is connected.
Make sure to remove the foam ring inside the camera housing before powering the
camera on for the first time. See 5.2 Installation (Indoor / Outdoor), page 6 for
details.
Maximum Length
Up to 1500ft
(455m)*
Up to 2300ft
(700m)*
Up to 300ft (91m)