TROUBLE SHOOTING:
IF THIS OCCURS
NO SPRAY
PUMP DOES NOT RUN
LOW SUCTION
NO SUCTION
LOW HEAT
NO HEAT
6 - FORM NO. 56041938 - ADVANTAGE 200H
CHECK THIS
Solution tank is empty, or fi lter is plugged up.
Clogged spray tip.
Pump not running.
Valve on wand not operating.
Solution hose not completely connected to hose or to machine.
This pump motor runs on AC voltage, so it should start running as soon as you turn on the switch. If
the pump motor does not start running, check the wiring to the switch and to the motor. Check the
switch to see if it is "open".
Debris is plugging cleaning tool or vacuum hose.
Drain gate is not completely closed, or seals are damaged.
Vacuum dome is not seated or is damaged.
Ball in the fl oat is blocking air fl ow. Turn off the vacuum so the ball will drop down.
No power to motor. Does the switch light up? If not, the switch may be bad or there
may be no power getting to the switch. Check wiring connections.
Test the switch.
Test the vacuum motor.
Spraying for too long will signifi cantly drop the heat. Try spraying for 8 - 10 seconds, or about three
strokes.
Heat exchanger needs to be fl ushed.
Wrong tool being used. Too much water passing through. Longer hose or larger diameter hose, than
standard.
Heat is not turned on.
No power in the wall outlet - check to see if the breaker has tripped.
No power to the heat switch - check wiring for 'opens."
No power out of heat switch. Replace switch.
Call your distributor for additional help.