Télécharger Imprimer la page

General Characteristics - CAME Z Série Mode D'emploi

Masquer les pouces Voir aussi pour Z Série:

Publicité

ENGLISH
Description of control panel
The ZBX7 control board is used as a
remote control for BX-A/BX-B series
230V single-phase automated sliding
gates.
The board is introduced and fixed in
place in the gearmotor's circuit board
holder (see assembly description on
page 12), at 230V (a.c.) in terminals L1
and L2.
The inlet is protected with two 5A fuses,
while the low voltage (24V) control
devices are protected with a 1A fuse.
The accessorie's total capacity (24V)
should not exceed 20W.
Photocells can be connected to obtain:
- Re-opening during closure (2-C1), if
the photocells identify an obstacle while
the gate is closing, they will reverse the
direction of movement until the gate is
completely open;
- Partial stop, shutdown of moving gate,
with activation of an automatic closing
cycle (2-C3);
- Total stop (1-2), shutdown of gate
movement without automatic closing; a
pushbutton or radio remote control must
be actuated to resume movement).
N.B : If an NC safety contact (2-C1, 2-
C3, 1-2) is opened, the LED (pag.14
-n°10) will flash to indicate this fact;
-4-

GENERAL CHARACTERISTICS

Safety
- Obstacle presence detection. When the
motor is stopped (gate is closed, open
or half-open after an emercency stop
command), the transmitter and the
control pushbutton will be deactivated if
an obstacle is detected by one of the
safety devices (for example, the
photocells);
Accessories which can be connected
to this unit
- Item. 001B4336 optical reader , detects
obstacles during the gate's movement;
during the opening phase, the gate
stops and then begins a closing
movement after the automatic closure
count, whilst during closure the direction
of movement is inverted.
Warning: during closure, if obstacles are
detected three times consecutively, the
gate will remain open and automatic
closure will be discontinued. To resume
the gate's movement, use the push-
button panel or the remote control;
- Cycle lamp . The lamp which lights the
manoeuvring zone: it remains lit from
the moment the doors begin to open
until they are completely closed
(including the time required for the
automatic closure). In case automatic
closure is not enabled, the lamp remains
lit only during movement.
The function of the cycle lamp is
obtained in output W-E1 only if dip
switch numbers: 1 "automatic closing"
and No. 6 "detect obstacle presence"
are set to ON (see page 16).

Publicité

loading

Ce manuel est également adapté pour:

Zbx7