B
C
D
Dual Tier Ultra Burner
A. Inner burner cap
B. Outer burner cap
C. Gas tube opening
D. Burner base
Even-Heat™ Torch Burner
A. Inner burner cap
B. Inner burner base
C. Outer burner base
D. Burner support
E. Gas tube opening
7. To Convert Standard Burner:
Use 7.0 mm wrench to loosen and remove the orifice
spud (A).
Set gas orifice spud aside.
Replace with correct LP gas orifice spud. See LP gas
orifice spud charts.
A
A. Orifice spud
8. To Convert Dual Tier Ultra and Dual Flame Burners:
Use 7.0 mm wrench to loosen and remove the inner
orifice spud (A) and the outer orifice spud (B).
Set gas orifice spuds aside.
Replace with correct LP gas orifice spuds. See the LP gas
orifice spud charts.
A
D
B
C
Standard and Dual Flame
A. Burner cap
B. Igniter electrode
C. Burner base
D. Gas tube opening
A
B
C
D
E
A
B
Dual Tier Ultra Burner
A. Inner orifice spud
B. Outer orifice spud
9. To Convert Even-Heat™ Torch Burner
Remove the spring that is shown in the following
illustration (C).
Use 7.0 mm wrench to loosen and remove the inner
orifice spud (A) and the outer orifice spud (B).
Set gas orifice spuds aside.
Replace with correct LP gas orifice spud. See the LP gas
orifice spud charts.
Return the spring to its original location.
C
A. Inner orifice spud
B. Outer orifice spud
C. Spring
IMPORTANT: Place Natural gas orifice spuds in plastic parts
bag for future use and keep with package containing
literature.
10. Replace sheet of insulation.
11. Replace burner bases and burner caps.
The igniter electrode is ceramic and could break during
conversion. Be sure that the electrode comes through the hole
in the burner smoothly while you are replacing the burner base.
A
A. Burner cap
B. Electrode
C. Burner base
12. Open shutoff valve in the gas supply line. The valve is open
when the handle is parallel to the gas pipe.
13. Plug in cooktop or reconnect power.
REMEMBER: Once you have completed converting all of the
cooktop burners, test the cooktop for leaks by brushing on
an approved noncorrosive leak-detection solution. If bubbles
appear, a leak is indicated. Correct any leaks found.
14. To adjust single and dual valves, see the "Flame Height
Adjustment" section.
A
B
Dual Flame Burners
A. Inner orifice spud
B. Outer orifice spud
A
B
B
C