5. Electrical connection

All electrical connections should be performed by a qualifi ed expert only!
Make sure all parts are free of tension before doing any maintenance work or electrical work.
The use of pumps for swimming pools and the restricted area around them is only permitted if pumps are
installed in accordance with DIN/VDE 0100 part 702. The supply circuit has to be protected with a fault
current contactor with a nominal fault current of I
has a disconnecting device, which allows disconnection from the power supply with a minimum of 3
mm contact gap at each pole. In accordance with norm requirements an electrical cable type H05RN-F
or H07RN-F must be used. Please ensure that the diameter of the electrical cable used adequately
accommodates for the power of the motor and the length of the cable. Pumps with A.C. motors are
equipped with a built-in thermal cut-out in the windings.

6. Initial start-up

Caution
Unscrew the ring nut and lift the transparent lid off the
housing. Slowly fi ll the pump with clean water until the water
level reaches the inlet connection. Put the transparent lid on
and tighten the ring nut by hand. Never let the pump run
dry, not even to verify the direction of rotation! Ensure
that the valves installed in the suction and pressure lines are
completely open. Never operate the pump without the strainer
basket. Before initial start-up and after extended periods of
downtime make sure the pump shaft turns freely.
7. Maintenance
Caution
The strainer basket must be cleaned at regular intervals.
A full or dirty strainer will impair the pump's fl ow rate and
the fi ltration. For longer periods of downtime we highly
recommend completely draining the pump and cleaning it.
Do not add water treatment agents, particularly agents in
tablet form, into the strainer basket.
Caution
If there is a risk of freezing, the pump must be drained ahead
of time. To do this open the drain plug and drain off all liquid.
Also drain all pipes subject to freezing. Before doing any
maintenance work, switch off the pump and disconnect it
from the power supply.
!
- 30 mA. Please make sure that the electrical installation
∆N
VD21.45.513-P
VD21.45.514-P
VD21.45.515-P