When working with the window function (Fno or Fnc) set the width
of the window by the difference between SP1 and rP1.
During the teach operation the window is set so that the current
system pressure (P
set the window
SP
HY
rP
Observe the instructions for installation and electrical connec-
tion (page 21).
Connect the unit according to the configuration:
1 x p-switching / 1 x IN (Teach)
BN
1
WH
2
4
BK
BU
3
Teach signal and acknowledgement signal with pnp operation = +U
Teach signal and acknowledgement signal with npn operation = -U
Core colours of ifm sockets:
1 = BN (brown), 2 = WH (white), 3 = BU (blue), 4 = BK (black)
After mounting, wiring and setting check whether the unit
operates correctly.
Explanation of the teach operation → page 22.
Explanation of the hysteresis and window functions → page 32.
) is in the middle of the window.
sys
P
P sys
1
0
1
0
L +
IN (Teach)
OUT
L-
teach operation
teach instant
1 x n-switching / 1 x IN (Teach)
BN
1
WH
2
4
BK
BU
3
acceptable
range
t
Fno
Fnc
L +
IN (Teach)
OUT
L-
B
B
27
5