Frost Protection Mode; Functional Check - Siemens REV23M Instructions D'installation

Table des Matières

Publicité

Press to accept.
(factory setting) will flash. Press to
accept or continue rolling toward the display to select one
of the following control modes:
, PID 6, PID 12 or
required control mode.
A brief description of the control modes is given below
(also refer to Fig.
).
Permanent self-learning adaptive control:
Suited for all standard applications (factory
setting).
PID 12 Normal controlled systems:
For locations with normal temperature variations.
PID 6
Fast controlled systems:
For locations with significant temperature
variations.
Difficult controlled systems:
Proper on / off controller with a switching
differential of 0.5 C.
4.2.5

Frost protection mode

Use operating mode selector
refer to Fig.
). If the standard value of 5 °C need to be
changed, the frost protection setpoint
changed via temperature menu T (refer to the Operating
Instructions).
5
Replace the controller
Proceed according to Fig. G.
6

Functional check

a) 60 seconds after the batteries supply power, an error
message
must appear
b) Switch on the boiler
c) The error message must disappear after 2 minutes at
the latest
d) Comfort mode
e) Select temperature menu T and adjust the temperature
setpoint
to 29 °C (refer to the Operating
Instructions)
f) Symbol
must appear on the display after
3 minutes at the latest. If that is not the case:
• Check the boiler
• The room temperature is possibly above 29 °C
g) Reset the setpoint temperature
(standard value 19 °C or individual setting)
h) Select the required operating mode
CE1G2266xx
. Press to accept the
to select symbol
(also
must be
to the initial value
7
Reset
User-defined data:
Press the button behind the pin opening for at least
one second: This resets the userspecific settings and the
"Permanent-self-learning operating mode" as well as
display of flow temperature, outside temperature and
d.h.w. setpoint to their default values (the heating engineer
settings will not be changed). The clock starts at 12:00.
During the reset time, all sections of the display light up,
enabling them to be checked.
All user-defined data plus the heating engineer
settings:
Press the button behind the pin opening together with the
warmer and colder buttons for at least one second.
After this reset, the factory settings will be reloaded (also
refer to section "Factory settings" in the Operating
Instructions).
Caution:
If the controller is removed from its base for
more than 30 seconds, an error message will
appear on the display.
When sliding the controller back to its base,
the error message must disappear after
2 minutes at the latest.
Without inserted batteries, reset functions
correctly for a maximum of 15 seconds only
after removing REV23M from its base.
8
Notes
• REV23M is an electric weekly programmable room
temperature controller.
• The controller conforms to "Software Class A" and is for
use in "normal" pollution situations.
• If the reference room is equipped with thermostatic
radiator valves, they must be set to their fully open
position.
• Remote operation contact T1 / T2 must be wired
separately using a separate shielded cable.
• Ensure that the local regulations for electrical
installations are complied with.
• REV23M can only be used in connection with an
OpenTherm Plus-compatible boiler.
03.07.2003
5/16