MAP Mix Provectus
Location Register read
0xA07A
M1 position
ADC10 value
(Read only)
0xA07C
M2 position
ADC10 value
(Read only)
0xA005
Voltage input
range:
2 - 10V or 0 - 10V
(Read only)
0xA004
Mixer type installed
(Read only)
Dansensor A/S
FR
Encoding
2 bytes unsigned integer
Range 0 to 1023
This is the external voltage input signal controlling the setting of the
CO
mixing for a 3-gas mixer.
2
For a CO
/O
mixer it controls CO
2
2
For N
/O
and CO
/O
mixers it controls O
2
2
2
2
Input range is 0 to 11.75V ~ 0 to 1023 ADC counts
For input range 2 to 10V for 0 to 100% mix, the ADC read-out range
will be approx. 174 to 871 counts
For input range 0 to 10V for 0 to 100% mix, the ADC read-out range
will be approx. 0 to 871 counts
Input must change more than 50mV from current setting before
new mix settings is recalculated.
2 bytes unsigned integer
Range 0 to 1023
Only present in a 3-gas mixer.
This is the external voltage input signal controlling the setting of the
O
mixing for a 3-gas mixer.
2
Input range is 0 to 11.75V ~ 0 to 1023 ADC counts
For input range 2 to 10V for 0 to 100% mix, the ADC read-out range
will be approx. 174 to 871 counts.
For input range 0 to 10V for 0 to 100% mix, the ADC read-out range
will be approx. 0 to 871 counts.
Input must change more than 50mV from current setting before
new mix settings is recalculated.
1 byte unsigned.
Readout of the range used for the two voltage input signals
controlling the mixer setting.
0 = range is 0-10V
1 = range is 2-10V (default)
1 byte unsigned
0 = No gas mixer
1 = CO
/N
(Gas 1/Gas 2)
2
2
2 = N
/O
(Gas 1/Gas 2)
2
2
3 = CO
/O
(Gas 1/Gas 2)
2
2
4 = N
/CO
/O
(Gas 1/Gas 2/Gas 3)
2
2
2
COPYRIGHT ©
Guide utilisateur
(gas 1).
2
(gas 2).
2
PBI-300864-F 06/2015
39