OPERATING INSTRUCTIONS

PRIOR TO OPERATION

The hilmor® Brushless DC Vacuum Pump motor is designed for 120 volts, plus or minus 10%.
1. Check the voltage at the outlet to ensure it matches the specifications on the hilmor®
position before connecting the pump to a power source. The light in the power switch
2. Fill the oil housing with hilmor® Vacuum Pump Oil by removing the oil fill cap and adding
oil until it has reached the level between Min and Max on the sight glass. Make sure
to fill with oil before switching the pump on. Oil capacity can be found on the hilmor®
3. Replace the oil fill cap and remove an unused cap on the inlet tree fitting. Make vacuum
4. Close the cap on the unused inlet tree fitting. After a few seconds, open the gas ballast
on the side of the pump. IMPORTANT: These are two separate actions and CAN
NOT be performed at the same time. The inlet cap MUST be closed before
5. After pump is running smoothly, close the gas ballast. The machine will typically
run smoothly after pulling to approximately 3,000 microns, depending on the
6.
TO PULL THE FASTEST VACUUM, FOLLOW THE TIPS BELOW
• Connect the machine directly to the system. Using a manifold slows the
• Use the hilmor® Valve Core Removal Tool at the system port to remove the Schrader®
• Use hilmor® Stainless Steel Evacuation Hoses for as many connections as possible.
• Connect a hilmor® Wireless Vacuum Gauge to the side port on the hilmor®Valve Core
Removal Tool to measure vacuum. Placing the vacuum gauge close to the pump will
SHUT-OFF
1.
2. Open an unused inlet tree fitting and continue to run the hilmor® vacuum pump for a
3.
4.