MAINTENANCE INSTRUCTIONS

This pellet vent system must be installed and serviced by a qualified chimney or venting professional.
The criteria for the inspection and maintenance must be in conformance with local or state building
codes, whichever has jurisdiction. It is recommended you use an inspection form and make notes that
you can review with the homeowner.

Maintenance Procedure

It is important that this venting system is checked and cleaned annually or as per stove manufacturer's
instructions. This is for the safety of the homeowner and is necessary to meet the warranty requirements
Vortex Pellet Vent Pipe
of
. During the heating season the venting system should be inspected for build-up
at least once every two months. If a build-up has accumulated, it should be removed immediately to
reduce the risk of a chimney fire.
It is recommended to clean thoroughly the pellet venting system after every heating season. During
summer, the air is damper and with minimal air circulation within the venting system, it can mix with
creosote and/or sooth deposits in pipes to form an acid that could accelerate the corrosion process
and induce premature decay of the steel. Have your pellet venting system cleaned by a professional
chimney sweep. Use a plastic brush
To clean the venting system it is recommended to perform the following:
1.
Remove the Cap by loosening the band clamp.
2.
Select the proper sized plastic chimney brush to clean the chimney.
3.
In some instances, proper cleaning will require removing the appliance and disassembling the
connector assembly to thoroughly inspect and clean parts that cannot be reached otherwise.
4.
Inspect and clean the Chimney Cap by loosening the clamp band. Spark arrestors and other
screens may be necessary or required in some areas, but may be susceptible to blockage from
fly ash or through freezing moisture in areas of low ambient temperature.
5.
Reinstall the Chimney Cap.
6.
Before the initial firing of the appliance, check the appliance's operating instructions for initial
firing precautions.
The venting system must be maintained in good condition and well maintained.
IF A SIGNIFICANT LAYER OF CREOSOTE HAS ACCUMULATED (3 MM (1/8") OR MORE),
IT MUST BE REMOVED IMMEDIATELY TO ELIMINATE CHIMNEY FIRE HAZARD.
Facing a Chimney Fire
• Evacuate family members and animals from the building, and then call the fire department.
• Turn off the unit.
Do not unplug it!
• If possible, use a chemical fire extinguisher, baking soda or sand to control the fire. Do not use
water as this may cause hazardous vapor explosions.
• Do not use the appliance until the venting system and the appliance have been inspected by a
qualified chimney sweeper or fire inspector.