QUICK START-UP

ALL FIGURES CAN BE FOUND ON PAGE 58
Check the content of the box for completeness and any possible transportation damage. If parts are damaged or missing, contact your local SDI
representative immediately.
FACTORY SETTINGS
The factory setting of the Radii Xpert's standard curing attachment is 20 seconds per exposure cycle.
CHARGING DOCK (FIGURE 1)
1.
Slide the correct AC adapter head into the power plug and plug into power supply. Tilt it slightly and apply slight pressure until you hear it snap
into place.
2. Plug the other end of the AC power plug into the back of the charging dock.
3. Place charging dock on a suitable flat table top and turn the power ON.
4. The LED lights on the charging dock will flash once from all red to all green to all blue. This indicates the unit is ready to use.
HANDPIECE (FIGURE 2)
1.
Remove the Radii Xpert handpiece from its packaging and place into the charging dock.
2. Allow the Radii Xpert to fully charge until status ring and all five lights on the charging base illuminate solid green.
Note:
1.
During charging the status ring and lights on the charging base illuminate pulsing green.
2. The Radii Xpert contains a lithium ion rechargeable battery that does not have any memory and can be recharged at any time.
OPERATING
1.
Remove the Radii Xpert handpiece from the charging dock and place a hygienic barrier sleeve.
Note: Ensure the Radii Xpert barrier sleeve fits flush over the lens without wrinkling/folds. Seam of the sleeve should be positioned down
the sides of the attachment and handpiece. (Figure 3)
2. Rotate the curing tip to desired position.
3. Press
(top button) and hold. A very low intensity light will illuminate to assist you to position the curing tip in the oral cavity. When the tip is in
the correct position, release your finger tip and curing will commence. Status ring illuminates solid blue with the standard curing tip attached. The
LCD displays 20, counting down to 0.
4. One long beep will sound when curing finishes and the status ring goes OFF.
5. Press
to start another 20 second cure.
6. To change pre-set curing time (temporary setting). Press
7.
Press
to scroll up through the options from last setting used. Press
8. Discard barrier sleeve after each patient.
9. Clean and sanitise the handpiece. See MAINTENANCE AND CLEAN section in this manual.
Note:
1.
Single patient use hygienic Radii Xpert barrier sleeve (100 pieces is included in each kit) is strongly recommended to prevent cross contamination
and protect the lens cap from dental material adhering to its surface and body. These sleeves have been especially designed to produce optimal
emission.
2. Light output may be significantly reduced if the wrong barrier sleeve is used or not correctly placed.
CURING TIME
1. Follow the recommended curing times published by the manufacturer of your restorative materials.
2. The indicated curing times usually assume the light tip is held at the correct position over the material being polymerized.
QUICK LIGHT INTENSITY STATUS CHECK USING THE BUILT-IN INTENSITY INDICATOR (FIGURE 4)
1.
Gently place the LED attachment tip on the test area of the
charging dock. Ensure the tip is level and central within the
test area. If not centered, it may give you lower readings.
4
and hold for 1-2 seconds. Numbers on LCD start flashing.
once to select. Numbers on LCD stop flashing.
2. Activate the light.
All 5 blue LEDs
4 blue LEDs
3 blue LEDs
2 blue LEDs
1 blue LED
100%
90%
80%
70%
60%