Membrane Replacement; Procedure For Extended Non-Use (More Than 2 Months) - Watts ZeroWaste PWRO4ZRO Manuel D'installation, D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Membrane Replacement

Order membrane by calling Watts at 1-800-224-1299
Item Needed: # 7100122,
Includes:
• (1) RO Membrane
This reverse osmosis system contains a replaceable component (the
RO membrane) which is critical to the efficiency of the system.
Replacement of this reverse osmosis membrane should be with one
of identical specifications as defined by Watts to assure the same
efficiency and contaminant reduction performance.
Membranes have a life expectancy between 2 and 5 years, de-
pending on the incoming water conditions and the amount the
RO system is used . This reverse osmosis membrane is critical for
effective reduction of total dissolved solids (TDS) . The product water
should be tested periodically to verify that the system is performing
satisfactorily .
Normally, a membrane would be replaced during a semiannual or
annual filter change . However, if at any time you notice a reduction
in water production or an unpleasant taste in the reverse osmosis
water, it could be time to replace the membrane . Watts recommends
replacing the membrane when TDS reduction falls below 75% .
A water sample may be sent to Watts for a free diagnosis of
your membrane performance. To send a water sample, use two
(2) clean containers and fill ½ cup
of tap water in one container and ½
cup of reverse osmosis water in 2nd
container. Clearly label each sample.
Send the samples to the address
listed on the cover of this manual at-
tention "Water Samples". Watts will
test the water and mail or call you
with the results.
Step A – Turn off the incoming water supply to the RO by turning the
knob on the Adapt-A-Valve™ clockwise until it stops .
Step B – Open the RO Faucet and allow water to drain from the tank
until it is completely empty .
Removing the Membrane
Step A – Use a
" wrench to remove the Green Tube fitting on the
5
8
left side of the horizontal membrane housing (end with one
elbow) .
Step B – Remove the cap from the membrane housing by turning it
counterclockwise to loosen .
A double sided wrench may be
purchased from Watts to aid with
loosening the cap / filter housings.
Step C – Remove membrane housing
from the holding clips . Using
a pair of pliers, grip the PVC
tube of the RO membrane and
pull firmly on the membrane to
remove from the housing and
discard .
Installing the Membrane
Step A – Lubricate the O-rings on the new membrane with a water
soluble lubricant such as KY Jelly ® . Insert the end with the
two black O-rings first into the
housing .
Step B – Once membrane has been
inserted into the housing you
must take your thumbs and
give a firm push to properly
seat the membrane . Replace
membrane housing cap and
tighten .
Step C – After replacing membrane
housing into clips, attach the
green tube to the elbow on
cap using
" wrench .
5
8
Step D – Follow the Start Up Instruc-
tions on Page 7 .
Procedure for Extended Non-Use
(More than 2 months)
Turn off the water supply by turning the knob on the Adapt-A-
Valve™ clockwise until it stops and open the RO faucet to empty
the storage tank (Save a few ounces of RO water) . Once the storage
tank is empty, remove the membrane and place it in a sealed plastic
bag with the RO water saved earlier and store in your refrigerator .
For restart, reinstall membrane (See Page 9 for membrane installa-
tion procedure) and follow startup procedure on Page 7 .