Door Board Overview - LiftMaster Cloud CAPXL Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INTRODUCTION

Door Board Overview

The CAPXL has a combination of access control inputs/outputs on the Door Boards that work in conjunction to control up to
4 access points.
DOOR BOARD 1
Door 1
WIEGAND INPUT
REQUEST
TO EXIT
STATUS
PRIMARY
RELAY
AUXILIARY
RELAY
WIEGAND
OUTPUT
INPUT/OUTPUT
Wiegand Input
Request to Exit
Status
Primary Relay
Auxiliary Relay
Wiegand Output
PRE-INSTALL
Door 2
WIEGAND INPUT
STATUS
REQUEST
TO EXIT
USED FOR
Proximity Readers, RFID Receiver, and Keypads (12 Vdc Power for readers only. Do not use to
power external devices)
External Free Exit Loop Detectors, Push Buttons, and Proximity Sensors
Door Sensors, Supervised Gate Operators, and EOL (End of Line) Wiring
Closed Door Sensor, Closed Gate Sensor, Supervised with EOL (End of Line) or unsupervised Gate
Operators, Door Strikes, and Maglocks
Gate Operator, Door Strikes, Alarm Shunt, Maglocks and Lights (for control only - power to be
provided by external supply
26 Bit Access Granted Activity for integration with third party systems
INSTALL
Door 3
REQUEST
TO EXIT
STATUS
PRIMARY
PRIMARY
RELAY
RELAY
AUXILIARY
AUXILIARY
RELAY
RELAY
NOT USED
6
NETWORK
ACCESS CONTROL
DOOR BOARD 2
WIEGAND INPUT
WIEGAND INPUT
Door 4
STATUS
REQUEST
TO EXIT
PRIMARY
RELAY
AUXILIARY
RELAY

Publicité