Installation - Electical
1.
Position the jumpers according to the input voltage, and then fi nish electrical connection to the door operator.
2.
When the maglock assembly and armature/strike plate are mated, the junction is Normally Open and the LED will turn to green.
3.
The remaining three terminals of the terminal block (COM/ NO/ NC) provide an auxiliary relay output which can be used as a door position
switch.
MAGLOCK PCB
-
+
Timer
0-90 sec
Power
Supply
incorrectly installed, but will draw
a higher current and may possibly
Typical Installation
** Important: Fix the armature plate not too tightly and make the rubber washer more flexible in order
to make the armature plate automatically adjust its proper position with the magnet
CAUTION
Unit may work if jumpers are
damage the assembly.
DOOR SENSOR SENSOR
* When "SW" is OFF, the Door Status
Sensor (REED SWITCH) detects if the
door is well closed.
DOOR SENSOR (Reed SW.)
NC
BLACK
C
NO
GREEN
Reed switch dry contacts are
rated max 3w (max switching
contact 0.25 A) for safe operation.
Do not exceed the rating.
RED