NOTICE
1. The product should only be powered by a UL listed power supply Regulated Power Limited power source.
2. Relay output is designated as Common.
3. Same Room Install – Resistive.
4. Installation Location: Indoor Dry.
Installation & wiring in compliance with ANSI/NFPA70 requirements
Wiring must be cased to avoid outer cable damaged, affect the insulation distance
Terminal: 12~22AWG
5. If power switch is not wired between DC source voltage and magnet, it will take a longer time to de-energize the
magnet simulating residual magnetism.(see below)

Installation Tips

1.
DO NOT touch the lock face with your hands.
2.
Should the surface plating be damaged, use a soft, clean dry cloth or abrasive cloth to clean the lock face. DO NOT use sand paper. A rust
inhibitor can be applied to the armature/strike plate and maglock assembly face.
Printed Circuit Board Schema�c