1- Air flushing
Slowly fill the pipeline with water on completion of the installation.
Meter must be completely flushed to work correctly (cf.
LCD after correct flushing (cf.
LCD after incorrect flushing. Air in pipe icon blinking displayed. (cf.
2- Pulse output connection (cf.
1- Brown = Not Used
2- White = Pulse
3- Blue = Ground
4- Black = Direction
5- Grey or Yellow/Green = Cable cut Tamper
3- Environmental Protection
Environmental Temperature
Storage Temperature

Transport

Electromagnetic Class
4- LCD overview
4.1 General LCD overview (cf.
The lid must be closed to better protect LCD display against direct sunlight.

4.2 Display overview

Icons
1
2
3
4
5
6
7
8
).
2
)
4
1°C to 55°C
-20°C to 70°C (during max 1 year, and max 4 weeks T> 35°C)
Min -25°C (< 72 hours continuous)
Max +70°C (< 72 hours continuous)
E2
E1 (for pulse output)
)
5
Information
Main display 10 digits
System or Application alarm
Water detection
Battery alert
Units flow and volume
Reverse flow
Flow direction
Leak indicator
).
1
).
3
Dry (air in pipe for more than 15 secondes)
Is set under specific conditions
Both indicators are off if no water in pipe or Q < Q
Permanent
Rolling display :
Index, Flowrate, ...
Positive index
Negative index
Verification mode
Wet (water in pipe)
12 Months remaining battery
m
PER h and m
3
3
Forward flow > Q
start
Reserve flow < Q
start
Leakage
start