Description And Technical Data; Standard Equipment; Foreseen Use Conditions; Functioning - Tecno-gaz IGEN - HAND Notice D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Manuale d'uso, Operating manual, Notice d'emploi, Manual de uso, Betriebsanleitung

DESCRIPTION AND TECHNICAL DATA

Description
The automatic atomiser mod. IGEN-HAND is
mainly formed by two parts in plastic material:
the front guard which includes the area
where the hands are hygienization.
the door holding the container with the
disinfectant liquid and the unit controlling the
appliance.
Technical data
Supply voltage 12 V
Pumping unit 12 V d.c. - 20 W
Max. power absorption 20 W
Average hygienization time 3-5 secs
Weight 5 Kg.
Overall dimensions 405x270x220 mm

STANDARD EQUIPMENT

1 pcs set stickers
1 pce funnel
1 pce battery charger
1 pce operating and spare parts manual

FORESEEN USE CONDITIONS

The automatic atomiser mod. IGEN-HAND has
been planned and manufactured only for
hygienisér the hands in a quick and safe way.
The appliance is destined to professional and
industrial sectors, to medical-sanitary operators
or food-processing operators. It allows to get a
per fect hygiene of the hands while fully
respecting the skin surfaces and the surrounding
environment.
CAUTION:
Any other use different from the one described
above is to be considered as improper and
unrational, therefore the manufacturer will
decline all responsibility for any damage caused
to people or things if caused from an improper
use of the appliance.

FUNCTIONING

Put your hands confidently inside the working
area to start the process of hygienization through
the vicinity sensor.
WARNING:
For an effective use of the appliance, keep
rubbing your hands for the whole process of
hygienization.

TROUBLE SHOOTING

The appliance is still and does not start or
the orange lamp is lit.
Pour some disinfecting liquid in the tank as
explained in the chapter "Maintenance".
Check the fuse F1 located on the electronic
card and replace, if necessary.
If the light is off, the battery is exhausted.
The atomization of the disinfecting liquid
does not take place correctly.
Check if the electric pump works correctly
and, if necessary, replace it.
Check if all the tubes conveying the
disinfecting liquid are free and correctly
attached.
When approaching the hands to the
working area, the appliance starts with
difficulty.
Adjust on the electronic card the trimmer
which controls the sensibility of the sensors
and which may have lost its adjustment.
Adjust as explained in the chapter
"Maintenance".
The atomization time is too short or too long.
Adjust on the electronic card the trimmer
which controls the working time of the
electric pump which may have lost its
adjustment. Adjust as explained in the
chapter "Maintenance".
9

Publicité

Table des Matières
loading

Table des Matières