Determine the location of the Yuna; the dimensions can be found in appendix 2 technical
data.
The height under the fire (fig 1, H) is normally approximately 20 to 42 cm, this dimension
also depends on the ceiling height, see the line drawing in appendix 3 with dimensions.
The fire is suspended by means of a wall plate (fig 1, 2), determine dimension L ( =
underside wall plate)
Level the wall plate with the supplied M8 bolts and wedge cases (fig 1, 1-3-4).
Suspend the fire over the wall bracket, align the fire under the duct.
Secure the fire with the supplied outside thread anchors (fig1 , 5)
Then place the wall plate (fig 2 , 6) on the cams, make sure everything is neatly vertically
aligned, using the supplied outer thread anchors or plugs. In case of a rear connection, use
one of the recesses (fig 2, 7)
Place the flue pipe (fig 3), secure it with a plate screw (fig 3, 10)
Slide the adjustable ceiling plate (fig 4 ,12) in the top cover (fig 4, 11)
Hang the top cover incl. ceiling plate with cams in the recesses of the upper plate (fig 2, 6)
Mark out the ceiling plate and attach it with the supplied screws and plugs (fig 4, 14-15)
Secure the top cover with the supplied bolts m6 (fig 4, 13)
Check whether everything is aligned. If necessary, the side plates can be adjusted with the
socket screws and the door by means of the flange nuts.
The Yuna is made with a lockable external air connection with a diam. of 80 mm. It can be
connected with a flexible heat-resistant pipe, so that combustion air can be drawn from
outside, independent of the installation room.
Check, prior to use, whether the vermiculite plates and the baffle plates are mounted
correctly in the fire (see user manual). If necessary, correct the position of the plates.
Place the possible floor plate under the fire.
If the fire is fired with a capacity of < 9 KW, or if the chimney is more than 5 metres long, or has a
lower heat resistance, you will have to insulate the single wall connection pipe with suitable
insulation material, over the correct length. As a result, the capacity is reduced and/or the flue gas
temperature is increased.
18