Troubleshooting: No Ionisation
Check mains supply and fuse on power unit. Replace fuse if necessary - see fuse details below.
The power unit has a current limitation of 5mA which ensures the safety of the system. If there is a
short on one of the bars it will try to draw more current than 5mA. When this happens the power unit
will shut down. Disconnect one bar at a time to discover which bar is causing the problem.
Health & Safety
The ozone generated by this product is less than 0.1ppm and within internationally accepted limits
Please note, when handling and cleaning, that the emitter pins are sharp and care is needed.
Spare Parts
Fuse in Power Unit: 20 x 5mm, value 400mA for 230V, or 800mA for 115V rated to 1500A.