Estoril
Insert
N-21
Steel chimney
Can be installed with steel chimney.
Weight including insert
Estoril
Estoril High
Safety distances (FIG 1)
Ensure that the safety distances are complied with.
Please note that these safety distances can vary from
country to country.
A
The distance from the glass in the door to a lateral
wall, measured diagonally, must be of at least 800 mm.
B
The distance between the top of the convection air
outlet and roof of inflammable material must be at least
500 mm.
The distance in front of the door opening of the insert to
inflammable materials/furniture must be at least 1 m.
*The illustration indicates the approximate center height
of the hole for the flue. Distortions in floors and walls
may influence the height. Dry stack the fireplace until
the mantelpiece element for accurate height and
positioning of the flue/chimney connection. If a
fresh air supply set is connected through the floor, mark
where the hole should be.
Assembly instructions (FIG 2 - FIG 25)
FIG 2 / FIG 13: Place the bottom plate in 90º relative
to the chimney/wall. If needed, adjust with wedges or
powder glue.
FIG 4 / FIG 17: If the fireplace is connected to a
chimney at the top, the smoke dome must be turned
229 kg
180º. Move the smoke lid to the rear flue outlet.
248 kg
FIG 6 / FIG 19: Make sure there is a gap between the
insert and the surround as the insert expand with heat.
Also read the section about adjustment.
Fresh air supply (accessory FIG A)
For more information see separate assembly
instructions for fresh air supply.
When the fresh air supply is passing through the floor, a
hole needs to be cut in the bottom plate of the fireplace.
See the illustrations in FIG A for recommended area for
the hole.
When assembling the Fresh Air Supply kit (accessory)
on Estoril High: it should be possible to hide the fresh
air supply pipe in the log chamber or conceal it with a
duct.