4. Remove the strain relief cap nut (7) and thread the dryer
power cord through it.
5. Continue threading the power supply cord through the
strain relief below the terminal access, temporarily leaving
the cap nut loose at this time.
6. Attach the power cord neutral conductor and one of the
BLACK wires from the line fi lter to the "N" terminal (3) on the
terminal block. Tighten the screw securely.
NOTE
If a terminal screw falls during cord installation, it can be retrieved
in the terminal screw recovery slot (8) below the access panel.
7. Attach the power cord ground (earth) conductor and the
CLEAR-coated wire to the "
block. Tighten the screw securely.
8. Attach the power cord "live" conductor and the other
BLACK wire to the "L" terminal (5) on the terminal block.
Tighten the screw securely.
IMPORTANT!
After installation ensure that earth wire is longer than power
wires.
9. Slide the strain relief cap nut up the cord and tighten
securely on the strain relief threads.
10. Reinsert terminal block cover and slide downward slightly,
ensuring lower retaining tabs are in place. Reinstall screw
removed earlier.
IMPORTANT!
Supplied strain relief fi ts supply cords ranging from 11.4 mm
to 18.0 mm. If your installation requires a cord outside these
dimension parameters, purchase and install the appropriate
strain relief from a local supply store.
" terminal (4) on the terminal
1
Access cover screw
2
Terminal block
3
Neutral ("N" terminal)
4
Earth/Ground ("
" terminal)
5
Live ("L" terminal)
6
Internal ground (GREEN screw)
7
Strain relief
8
Terminal screw recovery slot