If you have any problems, don't go back to the store - please contact us !
QUESTIONS
A. Introduction ............................................ 2
B. Safety Instructions .................................. 2
C. Technical Specifications .......................... 2
D. Installation .............................................. 3
a. Mounting the faucet .................. 3
b. Mounting the unit ...................... 3
c. Connecting the faucet ................ 4
d. Installing supply valve ................ 4
e. Start-up ...................................... 5
E. Maintenance ....................................... ...... 6
F. Cartridge Cleaning & Repl. Schedule ...... 6
G. Troubleshooting ..................................... 7
H. Parts List ................................................. 8
I.
Warranty ................................................ 8
Most issues can be resolved over the phone.
Canada Toll Free
1800 667 8072
Toronto and Area
(905) 884 9388
(Mon to Fri 8:30 AM to 5:00 PM EST)
www.rainfresh.ca/UCS3
CONTENTS
Tested and Certified by CSA International to CSA Standard B483.1, to NSF/ANSI Standard 53
for reduction of Lead, VOC, Cyst (e.g. Cryptosporidium & Giardia) and lindane, to NSF/ANSI
Standard 42 for reduction of chlorine, taste & odour, and to NSF/ANSI 372.
The standards referenced above evaluate products for use with disinfected waters.
_______________________________________________________________________________
Additional testing and verification for reduction of bacteria and particulates performed by
independent laboratory.
VIDEO INSTRUCTIONS
Or visit Rainfresh Youtube Channel

Publicité

Table des Matières
loading

Sommaire des Matières pour Rainfresh Drinking Water System 3

  • Page 1: Table Des Matières

    DRINKING WATER SYSTEM 3 (MODEL UCS3) USER MANUAL Thank you for purchasing one of our ENVIROGARD / Rainfresh Water Filters. We are committed to ensuring that you are totally satisfied. If you have any problems, don’t go back to the store – please contact us ! Most issues can be resolved over the phone.
  • Page 2: Introduction

    This system is intended for use with cold water only. DO NOT INSTALL ON HOT WATER. o Only use Rainfresh filter cartridges with this unit. No other filter cartridge will function with this system. o Do not lubricate head O-rings with petroleum based lubricants. Only food-grade silicone (Dow 111 compound) should be sparingly used.
  • Page 3: Installation

    (such as basement or crawl space) from where tubing can be run to the faucet. The unit should not be installed more than fifteen feet away from the faucet. Call Rainfresh if you have questions. Step 1: Mounting the Faucet Faucet may be installed in hole in sink if available or in counter top.
  • Page 4: Connecting The Faucet

    THE HIGHER AND CLOSER TO THE FRONT YOU MOUNT THE UNIT THE BETTER FOR REGULAR MAINTENANCE. 2. Partially screw the 3 mounting bracket screws (1011-0) into screw locations. Install mounting bracket and head assembly over screw heads and tighten screws. NOTE: If wall is too thin to accept screws then use round head nuts and bolts (not supplied) to mount bracket.
  • Page 5: Start-Up

     With rubber gasket in position clamp entire assembly to pipe using bolts provided. Tighten bolts, keeping brackets parallel until rubber gasket is firmly compressed. CAUTION: DO NOT OVERTIGHTEN. Do not turn handle yet.  Measure and cut (if necessary) remaining length of plastic tubing from the INLET fittings (2553). Slide compression nut (720-0) and compression sleeve (721-1) onto tube and put tube insert (722-0) into tube as shown in Fig.
  • Page 6: Maintenance

    Ceramic filter Bacteria, parasites, E. coli etc. 1 year Head seals 2502 1 year Sump** 5 years Call Rainfresh or order Vent pin assembly 2505 5 years online at www.rainfreshstore.ca Other parts *Note: Cartridge life is directly dependant on water conditions and volume of water filtered. Excessive sediment may cause more frequent replacement.
  • Page 7: Troubleshooting

    Water flow is slow Ceramic cartridge is dirty. See section E Water drips from faucet Replace faucet cartridge (1050-2). Call Rainfresh to order after turning faucet off Ceramic cartridge is Replace cartridge immediately. Broken or cracked cartridges are not under warranty...
  • Page 8 Company's obligation under this warranty shall consist of repair, replacement or credit, at its option, of any part found by the Company inspection to be defective, provided that the product has not been misused, abused, altered or damaged as determined by the Company and provided that only approved Enivrogard/Rainfresh replacement cartridges have been used in the housings.
  • Page 9 MANUEL UTILISATEUR Nous vous remercions d'avoir acheté un de nos systèmes de désinfection ENVIROGARD/Rainfresh. Nous nous engageons à vous donner entière satisfaction. Si l'article vous cause un problème, ne retournez pas au magasin. Appelez-nous ! La plupart des problèmes peuvent être résolus par téléphone.
  • Page 10: Introduction

     Ce système est destiné à être utilisé uniquement avec de l’eau froide. NE PAS L’INSTALLER POUR L’EAU CHAUDE.  Utilisez uniquement des cartouches filtrantes Rainfresh avec ce dispositif. Aucune autre cartouche filtrante ne fonctionnera avec ce dispositif.  Ne pas lubrifier la tête des joints toriques avec des lubrifiants à base de pétrole. Le silicone alimentaire (composé...
  • Page 11: Installation

    (modèle CK538) en ligne sur le site www.rainfreshstore.ca. Vous recevrez votre ½ po x ½ po x commande sous 2 à 3 jours ouvrables. Vous pouvez également appeler Rainfresh au 3/8 po 1 800 667-8072 et commander votre robinet d’alimentation par téléphone.
  • Page 12: Raccordement Du Robinet

    2. Installez le support et serrez les vis. REMARQUE: Si le mur est trop mince pour les vis, fixez le support avec des boulons et des écrous (non compris). Étape 3: Raccordement du robinet Mesurez la distance entre le robinet et le raccord de sortie (2554).
  • Page 13: Commencez

     Mesurer et couper (si nécessaire) la longueur restante de tuyau en plastique pour relier le collier de selle aux raccords INLET (2553). Glisser l 'écrou de compression (720-0) et le manchon de compression (721-1) sur le tube et insérer l' insert du tube (722-0) dans le tube comme illustré...
  • Page 14: Utilisation Et Entretien

    Filtre en céramique Bactéries, parasites, E. coli, etc. Un an Joints de tête 2502 Un an Carter** Cinq ans En appelant Rainfresh ou en Montage de la tige de 2505 Cinq ans commandant en ligne sur le ventilation site www.rainfreshstore.ca Autres pièces * Remarque: La durée de vie des cartouches dépend directement des conditions d'eau et du volume d'eau filtré.
  • Page 15: Dépannage

    Le débit d’eau du robinet est lent La cartouche en céramique est sale. Voir la section E. L’eau s’écoule du robinet après Remplacez la cartouche du robinet (1050-2). Appelez Rainfresh pour en commander une. que le robinet a été fermé. La cartouche en céramique est Remplacez la cartouche immédiatement.
  • Page 16 à remplacer (à sa discrétion) toute pièce qu'elle juge défectueuse, pourvu qu'elle ne détermine pas que le filtre a été modifié ou qu'il a été utilisé incorrectement ou de façon abusive, et pourvu que seules des cartouches Rainfresh aient été utilisées dans le filtre. Cette garantie ne couvre pas les cartouches de rechange. Leur rendement diminue à...