INSTRUCTION FOR USE

OPERATING GUIDE

WARNING!
On some points of the machine there are some adhesive plates indicating:
-DANGER!
-WARNING!
-CAUTION!
-CONSULTATION
While reading this Manual, the operator must pay particular attention to the symbols shown on the plates. Do not cover these
plates for any reason and immediately replace them if damaged.

BATTERY CHECK/SETTING ON A NEW MACHINE

WARNING!
The electric components of the machine can be seriously damaged if the batteries are either improperly in-
stalled or connected. The batteries must be installed by qualified personnel only. Set the function electronic
board and the built-in battery charger according to the type of batteries used (WET or GEL/AGM batteries).
Check the batteries for damage before installation. Disconnect the battery connector and the battery charger
plug. Handle the batteries with great care. Install the battery terminal protection caps supplied with the ma-
chine.
6V
6V
Back
12V
Back
12V
Figure 4
Batteries already installed on the machine
Ensure that the battery connector (29, Figure. 2) is connected.
1.
When first using the machine with new batteries, perform a full charging cycle (see the procedure in Maintenance chapter).
2.
Without batteries
Buy appropriate batteries (see "Technical Data" paragraph). For battery choice and installation, apply to qualified battery Retailers.
1.
Set the machine according to the type of batteries installed as shown in the Super User key section of the Maintenance chapter.
2.
6V
Front
6V
Battery fixed plate
Front
NOTE
The machine requires two 12V bat-
teries or four 6V Batteries, connected
according to the diagram (Figure 4).
Put the battery fixed plate correctly
as (Figure. 4).