LEGENDA SIMBOLI

Simbolo
~
ENGLISH
WARNING: In this document, just a number of basic indications on the product are present
For further detailed information, refer to MP500 control panel manuals.
Power supply in CAT II 2500 V. Once installed, the power supply is subject to transient voltages
higher than those of the overvoltage category for which is was designed. For this reason, an
additional transient voltage protection is required outside the device.

GENERAL DESCRIPTION

AS500 additional power supply unit is an optional device of MP500/8 and MP500/8 control panel.
AS500 unit is provided with an electronic board integrating inside itself an EP508 type expansion
that is directly connected to control panel BUS, a repeater module to extend control panel BUS
length and an additional power supply unit able to feed devices connected to the system.
The AS500 unit is provided with:
 8 inputs;
 1 balanced SAB input;
 3 outputs (1 relay output and two electric outputs);
 1 switching power unit;
 battery housing;
 housing for two expansions.
INSTALLATION
F
8
Tensione di alimentazione continua
Tensione di alimentazione alternata
Riferirsi al manuale d'installazione del dispositivo
D
T
F
AS500/RPT
Spiegazione
T Wall fixing holes
D Fixing holes for 2 optional EP508 expansions
F Strip fixing ring for power supply cable