To make the ground connection of the equipment, crimp the spade terminal "A" (supplied) to
the ground wire that should be inserted into one of the spade terminals on the wall of the
container (C).
2.
Connect ground cable to cover Faston connector (B).
3.
Secure the wires by fastening them in anchoring point (F) with the strip provided.
Wires with cross-section area of 0.5 mm² or larger must comply with IEC 60332-1-2; wires
with cross-section area smaller than 0.5 mm² must comply with IEC 60332-2-2.
Use battery:
Type VRLA (Valve Regulated Lead Acid)
Casing: UL94V-1 or higher flammability rating
Comply to IEC 60896-21: 2004, IEC 60896-22: 2004
must only be replaced by experienced and qualified personnel
AS500/RPT CIRCUIT
10
F
AS500/RPT
6,3 x 0,8 mm female
faston terminal
6,3 x 0,8 mm female
faston terminal