TECHNICAL CHARACTERISTICS

BUS IN - Section
Nominal power voltage
Expansion operating voltage
Maximum current draw of expansion at 12 V⎓
(with relays energised, factory setting)
Maximum current draw of expansion at 12 V⎓ (with
relays de-energised)
Nominal voltage on pin +V1:
Max. current that can be supplied from pin +V1:
Nominal voltage on pins +V2:
Max. overall current that can be supplied from pins +V2:
U1 output relay contact switching max. current and voltage:
Max. current that can be supplied from U2 and U3
electric outputs:
Max. total length of control panel-peripheral BUS line
(primary BUS)
Max. connection length between each sensor or
actuator and expansion
Max. length of connection between a fast (roller,
shock, ...) detector and the expansion:
Supplementary power section and BUS OUT
Nominal power voltage
Max. current absorption at 230 V (PS534–MW RS-50-15) 800 mA
PS534 power output nominal voltage (MW RS-50-15)
type A power supply
Max. current that can be supplied:
Max. current absorbed from power supply / repeater
electronics
Allocable battery
Battery charging nominal voltage
Max. current supply to charge battery
Max. time for recharging battery to 80%
Battery low threshold
Battery release threshold
Automatic battery test (controlled by control panel)
Max. current for external devices (keypads, sensors, sirens):
taken from + (BUS OUT), +, + terminals
Degree2–with ATS2 communication and 12 hrs autonomy
(total 1150 mA, of which 100 mA for electronics)
Nominal voltage on pin +SR
Max. current that can be supplied from pin +SR:
Nominal voltage on pin + (BUS OUT)
Max. current deliverable from + (BUS OUT) terminal
Nominal voltage on pins +
Max. total current deliverable from +V terminals
Max. total length of serial power supply-peripheral
BUS OUT line (secondary BUS)
Note 1): if battery is disconnected, at the ends of pin +BT –BT, no voltage is present.
Note 3): in case of lack of power supply, +SR provides no voltage.
13,8 V⎓ (supplied by control panel BUS)
9 V⎓ ÷ 15 V⎓
50 mA stand-by with balanced inputs
55 mA with NC inputs
40 mA with balanced inputs
45 mA with NC inputs
13,2 V⎓ (supplied by control panel BUS)
500 mA (with overload protection)
13,2 V⎓ (supplied by control panel BUS)
500 mA (with overload protection)
1 A – 24 V⎓ with resistive load
10 mA
400 m
500 m
100 m
230 V~ +10% -15% 50/60 Hz
14,4 V⎓
3,4 A
100 mA
12 V – 18 Ah
note 1) 13,8 V⎓
500 mA
48 hours
11,5 V
10,5 V
every 24 hours (with mains)
1050 mA
note 3) 14,4 V⎓
200 mA (with overload protection)
13,8 V⎓ ±1,5%
1100 mA (with overload protection)
13,8 V⎓ ±1,5%
750 mA each (with overload protection)
400 m