6. CONNECTING CONDITIONS

6.1 Connection to 1-phase network
The charger is suitable for a mains voltage of 230V - 50/60Hz, 1-phase and has been
fitted with a 1.9 meter mains lead and plug.
NOTE: Check whether the mains voltage is in accordance with the voltage the charger
was designed for.
The mains plug should be plugged into a wall socket.
6.2 Connection charging cables
On the output (secondary) side the chargers have been fitted with a 2.4 meter 3-wire
core charging cable. As the charger takes cable loss it is not allowed to replace this
cable by a cable with a different length and/or diameter without adaptation by the
supplier/dealer. Shortening the cable is therefor not allowed!
Figure 1 XLR-charging connector
The charging cable can be supplied together with an XLR-charging connector, whereby
pin 1 of the XLR-charging connector is the positive pole (+) and pin 2 is the negative pole
(-) and pin 3 is the drive inhibit signal (unless this is altered by your supplier/dealer).
In case the charging cable is supplied without a charging plug, this ought to be supplied
together with the battery. When mounting this plug you should observe the polarity.
The positive of the battery is connected to the positive of the charger and the negative of
the battery is connected to the negative of the charger. If the battery is connected to the
charger with reversed polarity, the charger will not start charging and does not show any
failure indication.
7