Notes; Connections; Technical Data (Extract) - FEIG Electronic MWD BP Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Quick Reference Guide

5 Notes

The MWD BP is a 2 channel device. While opening parameter entry first the odd address used to open chan-
-
nel 1 will displayed. The following even device address activates channel 2.
In factory settings relay 1 with change over contacts is assigned to channel 1 (display „
-
normally open contact is assigned to channel 2 (display „
parameter entry.
Only the odd device address of channel 1 can be changed. The address of channel 2 results from the following
-
even address.
Common parameter (e.g. firmware info, profiles...) can be displayed/changed with even or odd device ad-
-
dress.

6 Connections

8

7 Technical data (extract)

Dimensions
Protective system
Power supply
Power consumption
Admissible working temperature
Storing temperature
Air moisture
Transmit frequency
Output power (EIRP)
Output relay
max. switching load
min. switching load
Maximum mounting height
Please look in the manual MWD BP for additional data !
BP-Quick_Ref_06_05_12.doc
Radar Motion Detector MWD BP
1
2
3
4
X1
NC
Com
NO
GND 24V NO
1
1
1
Backside view, Contact status for power off
135x65x130mm (BxHxT)
IP 65
12-27 V AC / 12-30 V DC
typ. 1,0 W, max. 2,4 W
-20 °C .. +60 °C
-30 °C .. +75 °C
< 95 % not condensing
typ. 24,125 GHz
typ. 40 mW, max. 100 mW
1 A bei 30 V AC/DC (resistive load)
1 mA / 5 V DC
7 m
mt 2006-05-12
."). It is possible to change relay assignments via
| |
6
5
7
Com
2
2
FEIG ELECTRONIC GmbH
7/8
|
.") and relay 2 with

Publicité

Table des Matières
loading

Table des Matières