Electrical Installation; Electrical Components; Torque Settings - Eco-King Saga Xpress SX 200 Instructions De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.6 Electrical installation

Fixed electric fittings should be used for in-
stallation in new homes or when changing an
existing electrical setup in accordance with
regulations. A mains cable with plug for wall
socket can be used when replacing the prod-
uct without changing the electrical setup. Any
fixed electric fittings must be installed by an
authorised electrician. The relevant standards
and regulations must be followed.

3.6.1 Electrical components

Component
Safety thermostat
Work thermostat
Heating element
Internal wires
A) Black wire (L1) – Neutral – connected to
point '1' on the lower safety thermostat.
B) White wire (L2) – Live – connected to point
'3' on the lower safety thermostat.
C) Yellow wire with green stripe
connected to the terminal for the heating
element in the lower panel (hexagonal
brass)
D) Internal wires from the thermostats to the
elements are connected as shown in the
electrical connection diagrams (right).
3.6.4 Fitting instructions
!
The product must be completely filled with water before the power is switched on.
Do not remove the junction box covers until the power supply to the product is switched OFF.
Do not attempt to repair or replace any electrical component installed in the product before the
power supply is switched OFF.
Do not use the product with a voltage other than what is specified on the product data plate.
Do not connect the power supply wiring to anywhere other than the product's main power
connection. DO NOT bypass the safety thermostat.
The product must have a clearance for servicing of minimum 40 cm in front of the junc-
!
tion box covers and sufficient space for servicing above the top.
3.6.5 Fitting recommendation
-
Mains cable should be hidden under one of the channels in the bottom of the product, see pt. 3.5.6.
-
Always follow local codes or CSA C22.1 Canadian Electrical Code.
10
Note
98°C thermal cut-out
60-90°C adjustable
1-phase 230 V
Heat-resistant
– Earth –
!
WARNING
!
CAUTION
RECOMMENDATION
3.6.2 Electrical connections in the junction box
!
Constant voltage present in junction boxes. Be-
fore any electrical work is done, the power sup-
ply must be disconnected and secured against
activation while the work is in progress.

3.6.3 Torque settings

Component
5/4" heating element
Thermostat screws
Screw on the element head 2 Nm (+/- 0.1)
WARNING
Torque
60 Nm (+/- 5)
2 Nm (+/- 0.1)

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Saga xpress sx 300

Table des Matières