AUTO MODE

This operating mode allows the user to configure different temperature values for each hour of each day of the week. The
"Comfort" / "Eco" temperatures and the related time intervals can be thus programmed. To activate this function, press the
[PROG] button until the "Chrono" icon is displayed. The setting of the Auto mode is as follows:
First the day and the hour must be set:
-
Enter into "Stand-by" mode and press the [-] button at least 3 seconds.
-
On the upper part of the display the message "Set" will be displayed
-
To set the day and the hour, use the [+] key to select "TED" at the bottom of the screen
-
Press the [Prog] button to enter the editing mode
-
The blinking arrow indicates the currently selected day: Pressing the [+] / [-] buttons the desired day can then be set
-
Press again the [Prog] button to confirm the selected day. After that, the procedure for entering the time starts and
the display shows the
currently selected time. "Hours": Use the [+] and [-] buttons to set the correct hour and confirm the selected value
pressing the [Prog] button. Minutes: Same procedure as for the hours. Confirm the selected value by pressing the
[Prog] button.
-
At the end of the procedure, the thermostat returns into "Stand-by" mode.
The weekly program can then be set:
-
Enter into "Stand-by" mode and press the [-] button at least 3 seconds.
-
On the upper part of the display the message "Set" will be displayed
-
To set the weekly program, use the [+] key to select "Prog" at the bottom of the screen.
-
Press the [Prog] button to enter the editing mode
-
Now a time sequence can be defined for each day of the week.
The procedure starts with day 1, and the desired sequence can be configured with the [+] and [-] buttons: For each
hour of the day, it is then possible to assign either the "Comfort" temperature (full bar indication displayed) by pressing
the [+] button or the "Eco" temperature (empty bar) by pressing the [-] button. Press [PROG] to confirm the entered
configuration for day 1, and repeat the same procedure for the remaining 6 days of the week.
4.
KEY LOCK
It is possible to lock the buttons of the device to avoid inadvertent modifications of the settings. Press the [PROG] button for 3
seconds to lock all the buttons except the [On/Stand-by] button. The key-lock icon is activated on the display. To unlock the
buttons press again the [PROG] button for 3 seconds. The key-lock icon disappears on the display
5.

OPEN WINDOW DETECTION

The Open Window Detection enables detecting of an open window by sensing a sudden decrease of the temperature in the
room. In such a case, the device deactivates the heating element for a maximum of 30 minutes or until an increase of the room
temperature reveals that the window has been closed. To activate this function:
-
Enter into "Stand-by" mode.
-
Press the [+] button for 3 seconds.
-
Press the [+] button to activate / deactivate the function
-
Press the [Prog] button to commit and return into "Stand-by" mode. When this function is enabled, the "Open Window
Detection" icon on the display is lit. When the device detects that the window is potentially opened, the "Open
Window" icon starts blinking When the function is disabled the "Open Window Detection" icon is not shown on the
display.
Note:
The device could fail in detecting an opened window e.g. if the thermostat is located on an isolated area of the room and far
from air currents or if the thermostat is placed close to an external heating source, or if the temperature variation in the room is
too slow.

TECHNICAL SPECIFICATIONS

- Power supply: 230VAC - 50Hz
- Power cable: 0,5m with Schuko plug socket
- IP 44, insulation class II
- After a power cut that lasts longer than 5 minutes, only the day and the hour have to be reset.
- Standards:
EN 62233:2008
EN 55014-1:2006 + A1:2009 + A2:2011
EN 55014-2:1997 + A1:2001 + IS1:2007 + A2:2008 EN 61000-3-2:2014
EN 61000-3-3:201
-This appliance complies with the European directive 'ECO Design Directive 2015/1188 and approval mark: