Storage; What If There Are Problems; Replacement Parts And Wearing Parts; Technical Specifications Le 30 - Beurer LE 30 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 21

8. Storage

If you do not plan to use the device for 2 to 3 days, we recommend that you unplug it and store it thoroughly
empty, clean and dry in the original packing in a dry environment. Ensure that no objects are placed on top
of the device.

9. What if there are problems?

Problem
The device is not working.
The device automatically
stops when dehumidifying.
The device is working but
is not reducing the relative
air humidity enough.

10. Replacement parts and wearing parts

Replacement parts and wearing parts are available from the corresponding service address (according to
the service address list). Please state the corresponding order number.
Designation
Plastic cover with filter
Water tank
Condensate hose

11. Technical specifications LE 30

Model
Mains voltage / power
Protection class
IP protection class
Dimensions (L x W x H)
Weight when empty
Recommended room size
Maximum tank capacity
Dehumidifying capacity
Cooling agent / quantity
Permissible operating temperature
Cause
The device is not connected to
mains power supply.
The device has switched itself off
due to safety reasons.
The water tank is full.
The water tank was not put back
in correctly.
The air filter is blocked.
The ambient temperature is below
0°C.
The ambient temperature is above
40°C.
The room is too big.
The air filter is blocked.
The air intake/air outlet is blocked. Ensure that the air intake/outlet is not
There too much exchange of air in
the room.
LE 30
See type plate on the device
I /
IPX0
290 x 190 x 478 mm
approx. 9.5 kg
20-30m²
approx. 1.8 litres
approx. 10 litres/24 h (30°C room temperature / 80% relative humidity)
R 134a, 92 g
5°C – 35°C 
Solution
Connect the mains plug and switch on
the device.
Clean and refill the device before next
use. Then switch it on again.
Empty the water tank, then start up the
device again.
Put the water tank in the correct posi-
tion.
Clean the air filter.
The ambient temperature must be
above 0°C.
The ambient temperature must be
below 40°C.
The device is only suitable for a room
size of up to 30 m².
Clean the air filter.
blocked.
Close the windows and doors.
Item number and/or order number
163.833
163.831
163.647
20